FAULT CODE
FAULT DESCRIPTION
abnormal: The control
E1
and computer has
abnormal communication
E2
No Speed Wireless
E3
Sensor Network
E4
Incline self-learning fault
E5
Over-Current Protection
Controller self-checking
E6
E7
EEPROM is broken
Communication
after start
Explosion-Proof
Protection
error
FAULT PROCESSING
Stop and go into fault. The machine can't running, the computer
shows fault code "E01", and the buzzle will ringing three tone.
Possible reasons:Communication obstructed between
controller and computer, please check the wire and make sure
the wire connect well and the wire without and danger.
Stop and go into fault. The machine shows fault code "E06".
Other areas show blank, and can not restart.
Possible Reason: Check the motor wire if connect well, and then
connect it again.
Possible Reasons : Can't receive the motor speed sensor
feedback above 3 seconds, please check sensor plug
motor connect wire and the controller.
Check incline motor sense wire and AC wire are inserted well;
AC wire is right inserted according to the indentify in the incline
motor; make sure the incline motor wire without damager; after
check those, press the button on controller, then start self-
learning again.
Stop and go into fault status, computer shows fault code
"E03".Other areas show blank. After 10 seconds will go into
ready mode, and can restart.
Possible Reasons:Over the rated load cause too much electricity
that make system Self-preservation or some parts blocked and
make DC motor can't process. Adjust the machine and restart.
Another please check the DC motor or controller have any
burned smell or not. If yes, please change the motor or
controller. Another make sure the power and voltage is comply
with standard.
Change the controller.
Change the controller.