5. Continue operating the pump handle as required to
raise load to the desired height.
6. Model GBJ-100 only: After load is partially raised and
pumping eff ort noticeably increases, move the pump
handle to the high pressure pump. Continue pumping
until the load is raised to the desired height.
WARNING: Model GBJ-100 is equipped with a
pressure gauge calibrated to indicate the
approximate weight being lifted. STOP pumping
immediately if the gauge reading exceeds 100 metric
tonnes [980  kN]. The jack is not designed to lift loads
greater than 100 metric tonnes (110 short tons).
7. Immediately after lifting is completed, support the
load with jack stands of the appropriate weight rating.
5.3 Lowering the Load
1. Operate pump handle one or two strokes, so that
the load is raised off of the jack stands. Remove jack
stands from under the load.
WARNING: Turn the release valve slowly in the
following step. If release valve is opened too
quickly, the object being lowered may drop
suddenly, possibly causing the jack to become
dislodged from beneath the load. Serious personal injury
and/or property damage could result.
CAUTION: Avoid "shock loads" created by
quickly opening and closing the release valve as
load is being lowered. Shock loads may overload
the jack's hydraulic circuit and damage the jack.
2. Using rectangular end of pump handle, slowly turn
the release valve stem counter-clockwise until the
valve opens and the ram begins to retract (do not turn
more than two revolutions). Allow the ram to continue
retracting until the load is fully lowered.
3. Remove jack from the lifting area.
4. Press down on the ram to return it to the fully retracted
position. Turn the extension screw (if equipped) all
the way down so that threads are fully recessed and
protected from damage.
5.4 Horizontal Operation (all models except GBJ-100)
When operated horizontally, the jack must be oriented
so that the pump is positioned down - closest to the
ground. The jack will not operate properly if the pump
is positioned up. See Fig. 5 for horizontal operating
positions.
WARNING: Support the jack during horizontal
operation so that it does not drop.
WARNING: Jack capacity is 50 percent or less
than normal rating when operated horizontally.
Use care to ensure that jack is not overloaded
during horizontal operation.
WARNING: Always use appropriately rated
blocking and/or supports to retain objects that
have been pushed apart and/or that are under
tension. Never place your hands, feet or body in between
objects being supported only by the jack.
4
Do NOT exceed 50% of the jack's rated
capacity during horizontal operation.
OK
OK
Fig. 5 - Horizontal Operation (all models exc. GBJ-100)
Note: Model GBJ-100 should not be used in the
horizontal position.
6.0 MAINTENANCE
6.1 Adding Hydraulic Oil
If oil level is low, add additional oil as described in the
following steps. Be careful to avoid dirt entry during
fi lling.
1. With ram fully retracted, set the jack in the upright
position. Be sure surface under jack is level.
2. Remove the oil fi ll/air release plug. On all jacks except
model GBJ-100, the plug is located on the side of the
cylinder housing. On model GBJ-100 only, the plug is
located at the top of the cylinder housing.
IMPORTANT: Use only Enerpac HF Series hydraulic oil
(ISO Grade 32) poured from a clean container.
WARNING: The use of motor oil, brake fl uid,
alcohol,
glycerin,
unapproved fl uids will damage the jack,
resulting in possible failure or malfunction of the device.
Personal injury and/or property damage may occur.
3. All models except GBJ-100: Fill until oil level is even
with bottom edge of the oil fi ll hole. See Fig. 6.
4. Model GBJ-100 only: Fill until oil level is about 3
inches [75 mm] below the oil fi ll hole. See Fig. 7.
Fig. 6 - Oil Level,
all models
except GBJ-100
NO
NO
vegetable
oil
or
other
Fig. 7 - Oil Level,
Model GBJ-100 only