Remote Control - see Fig. 3
In addition to the previously mentioned controls, the remote
control also has the following two controls:
Thermostat Control Buttons- Adjust the temperature set
point to your individual requirements. Once the desired
set temperature is reached the heater will cycle on and
off to maintain the desired set temperature. The floating
display shows temperature in degree Celsius, the
default temperature is 22°C. The range of temperature
is between 5-32°C. The set temperature can be seen
for 5 seconds after selection in the floating display
shown in Fig.1.
1. To activate the remote control remove the battery isolation
strip, which is used to ensure your remote control reaches you
fully charged. See Fig. 3
2. To replace the remote control battery, turn over the remote
control, and follow the diagram embossed on the remote control.
3. Only use CR2025 or CR2032 size of batteries.
Fitting Fire Box- see Fig. 5 & 6
The firebox is to be installed from the front of the mantle and
inserted so that the flanges are flush against the front surface
of the mantel or opening.
Depending upon availible space within the mantel or opening the
firebox can be secured in place, using the L-Brackets supplied
with this product, to fit these brackets please follow the steps
shown in Fig. 6.
WARNING: DO NOT INSTALL THE FIREBOX DIRECTLY ON
CARPET OR SIMILAR SURFACES.
Clearence for air circulation is provided by four felt feet at the
bottom of the firebox, installing directly onto carpet may restrict
air circulation. If you wish to install the firebox on carpet, place
a one-piece, solid, flat surface under the firebox. Ensure that all
of the feet rest securely on this surface.
Mantle
If fitting the product into a mantle the required opening is 587
(High) x 686 (Wide) x 191 (Deep)mm. Please see Fig. 5.
Thermal Safety Cut-out
A thermal safety cut-out is incorporated in the heater to
prevent damage due to overheating. This can happen if
the heat outlet was restricted in any way. The heater will
switch on once the obstruction has been removed and
the heater has cooled. If the cut-out continues to operate
intermittently, the heater should be switched off and a service
agent contacted.
Maintenance
WARNING: ALWAYS DISCONNECT FROM THE POWER
SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE.
LED lamps
This fire is fitted with LED (Light Emitting Diode) bulbs in place
of traditional incandescent bulbs. These generate the same
light levels as traditional bulbs, but use a fraction of the energy
consumed.
Cleaning
WARNING – ALWAYS DISCONNECT FROM THE POWER
SUPPLY BEFORE CLEANING THE HEATER.
For general cleaning use a soft clean duster – never use
abrasive cleaners. The glass viewing screen should be
cleaned carefully with a soft cloth. DO NOT use proprietary
glass cleaners.
To remove any accumulation of dust or fluff the soft brush
attachment of a vacuum cleaner should occasionally be used
to clean the outlet grille of the fan heater.
If the logs require cleaning remove the glass please see Fig.
4, and clean the using a duster or a vacuum cleaner with a
sodr brush attachment. Then replace the glass as per Fig. 4.
After Sales Service
Should you require after sales service or should you need to
purchase any spares, please contact the retailer from whom
the appliance was purchased or contact the service number
relevant to your country on the warranty card.
Please do not return a faulty product to us in the first instance
as this may result in loss or damage and delay in providing
you with a satisfactory service. Please retain your receipt as
proof of purchase.
Recycling
For electrical products sold within the
European Community. At the end of the
electrical products useful life it should not be
disposed of with household waste. Please
recycle where facilities exist. Check with your
Local Authority or retailer for recycling advice
in your country.