DESCRIPTION
Power supply to be used for the burglar-alarm system power
supply together with the external siren item 4072A (optional),
made in modular container for DIN rail (8 modules).
It is designed for installation in surface-mounted switchboards
item F115/8A.
The power supply is made to be connected to a 12V battery
- (6.5 - 24) Ah for the system's back-up working.
It is recommended that the 7.2 Ah battery is installed on a
distribution board flush mounted to the wall using items
F496/FF and F496/PF.
The 24 Am battery is not cover
by IMQ Alarm certification
INSTALLATION
08W20
12V
230 ± 10% V~ 50-60Hz
08W20
I MAX= 300 mA
BUS 27V
1A BAT 400 mA
12V
T=5÷40°C F1= F5AL
1A BAT 400 mA
1
Connect the 230V a.c. power supply wires to the terminals (1)
and the telephone pair to the terminals (2).
Install the power supply inside the
switchboard item F115/8A
230 ± 10% V~ 50-60Hz
I MAX= 300 mA
BUS 27V
1A BAT 400 mA
T=5÷40°C F1= F5AL
2 3
08W20
12V
FEATURES
- Power supply: 230Va.c. ± 10% 50-60Hz
- Output: two wire
- Maximum current for burglar-alarm system: 700 mA
- Maximum current for automation system: 1A
- Battery charging current: 400 mA
- Rated voltage in output 27,5V d.c.
- System lifetime: see table BOX 5
- Degree of IP protection: IP30
- Operating temperature: (+5 ÷ +40) °C
- Protection against tampering by means of item L4630
- Performance level (CEI 79-2 standard): 2
- F1 Fuse: F5AL