Technical Features - Roger Technology B71/BC Serie Manual De Instrucciones

Ocultar thumbs Ver también para B71/BC Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
INDEX
1 Introduction to instructions and warnings

2 Technical features

4.1 Use of internal batteries with B70/2DC - B70/2B 17
6 Operating mode
1
Introduction to instructions and warnings
This manual is intended only for qualified
technical staff in charge with the machine
installation.
The informations in this Manual are not intended
for the final user.
This manual refers to batteries and battery
chargers of B71/BC, B71/BC/INT and B71/BC/
EXT series for control units B70/1DC, B70/2DC,
B70/2B and B70/2ML and should not be used for
other devices.
WARNINGS
2
Technical features
SUPPLY VOLTAGE:
MAXIMUM INPUT POWER
INTERNAL LEAD-ACID BATTERIES - B71/BC/INT
OPTIONAL EXTERNAL LEAD-ACID BATTERIES - B71/BC/EXT 2 x 12Vdc 4500mAh, connected in series
NOMINAL CHARGE VOLTAGE
MINIMUM SELF-PROTECTION VOLTAGE OF BATTERY
"BR" OPEN JUMPER CHARGE CURRENT
"BR" CLOSE JUMPER CHARGE CURRENT
OPERATING TEMPERATURE
PROTECTION RATING
PRODUCT SIZE
16
DANGER OF
ELECTRIC SHOCK
Carefully read this section before installing the
device.
16
In order to prevent the risk of electrocution and
16
injuries, before performing any intervention on
17
the device, please cut off the power supply and
17
one of the two battery poles. To prevent the risk
of burning, be careful to avoid generating short
circuits on battery terminals by contact with
17
braces or rings.
18
The machine must be installed only by qualified
18
staff, following the standards in force.
18
Perform the connections using appropriate cables
18
for the required current and voltage, respecting the
18
technical features of the product.
18
When installing cable glands (or fittings) on plastic
19
containers, secure them tightely to prevent water
19
from entering the box.
The battery charger is supplied with the positive
terminal of the battery disconnected, to maintain
their charging state: the installer is, however,
responsible to check that the connectin is
correct.
In the event of reversed connection, the red
LED "DL1" turns on and the circuit enters
in thermal protection mode: disconnect the
battery immediately and execute the connection
correctly.
Please keep in mind that in the absence of
voltage, but with the batteries connected, the
output terminals of the battery charger are under
voltage; therefore, handle the cables connected
to them very carefully.
16Vac ... 24Vac
15W
2 x 12Vdc 1200mAh, connected in series
27.6 Vdc
19.5 Vdc
250 mA (for 1200mAh batteries)
400 mA (optional, for fast charge of 4500mAh
batteries)
-20°C ... +55°C
IP00
dimensions in mm. 243 x 49 x 89 Weight: 1.5Kg