E N G L I S H
• Have repairs carried out only by the manufacturer
or authorised agents having due regard to the
information given in the manual and using the
appropriate tools and equipment.
• Do not disassemble or block any parts of the
fastener driving tool such as the safety yoke.
• Have the tool serviced properly and at regular
intervals.
The following pictograms are shown on the tool:
Pneumatic tool with safety yoke.
Do not use on a ladder.
Magazine angle.
Maximum number of nails in magazine.
Nail diameter.
Nail length.
Max. operating pressure.

Package contents

The package contains:
1 Nailer
1 Sequential action trigger
1 Pair of safety glasses
1 Bottle of D
WALT pneumatic tool oil
E
2 Allen keys
1 Kitbox
1 Instruction manual
1 Exploded drawing
• Check for damage to the tool, parts or accessories
which may have occurred during transport.
• Take the time to thoroughly read and understand
this manual prior to operation.
22
D51256.P65

Description (fig. A)

Your nailer D51256/D51275 has been designed for
driving fasteners into wooden workpieces.
1 Trigger/lock-off switch
2 Air fitting
3 Contact trip
4 Magazine

Assembly and adjustment

Trigger selection
These tools are assembled with a bump action
trigger. A sequential action trigger is also included
with the original packaging. For definitions of "bump
action" and "sequential action", see below.
- The grey trigger with a single nail printed on the
side is the sequential action trigger. Installation of
this kit causes the tool to function in sequential
action mode.
- The black trigger with three nails printed on the
side is the bump action trigger. Installation of this
kit causes the tool to function in bump action
mode.
Removing the trigger (fig. B)
• Disconnect the airline from the tool.
• Remove all nails from the magazine.
• Remove the rubber grommet (5) from the end of
the dowel pin (6).
• Remove the dowel pin.
• Remove the trigger assembly (7).
Fitting the trigger (fig. B)
• Select the appropriate trigger.
• Insert the trigger assembly into the trigger cavity,
ensuring that the trigger spring (8) is properly
seated.
• Insert the dowel pin (6) through the tool frame,
contact trip guide and trigger assembly.
• Push the rubber grommet (5) onto the end of the
dowel pin.
Air fitting (fig. A)
These tools have a standard 1/4" pipe thread for
the air fitting (2).
• Wrap the male end of the fitting with Teflon tape
to prevent air leaks.
• Screw the fitting into the end cap and tighten firmly.