GYS STARTPACK 12.24 CI Manual Del Usuario página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
Translation of the original instructions
For more information on the progress of the state of charge:
4 CHARGE
MAINTENANCE OF THE INTERNAL BATTERY
These high performance batteries require the user to be extra careful. By observing the instructions below, the life of
the batteries can be extended:
- Charge the appliance immediately after purchase and after each use.
- Do not use an external charger other than the one supplied with the machine.
- When not in use, set the switch (or battery switch) to OFF.
- Never short-circuit the clamps when the switch is on 12 or 24 V.
- Never connect the red clamp to the negative terminal of the battery and the black clamp (-) to the motor ground. This
will short-circuit the batteries in the Startpack.
- Wait 3 minutes before each start attempt. This allows the device to cool down and the batteries' voltage to recover.
Without this waiting time and if the start test lasts too long, there is a risk of losing power and reducing the chances
of starting on the following tests.
A product equipped with a lead battery must not be stored for more than three months from receipt of the goods. If this
is not the case, the battery must be recharged in order to keep its performance intact.
As a general rule, we recommend connecting the product permanently to maintain the batteries at their best level of
performance and increase their lifetime. If the maintenance rules are not followed, the internal resistance of the battery
will increase, causing it to deteriorate irreversibly over time.
The internal resistance is an important indicator for determining:
- if the battery has been well maintained by frequent recharging,
- if the booster has been stored in optimal conditions: in a dry place kept at room temperature (15°C to 25°C).
BATTERY NOT COVERED BY WARRANTY
Batteries are live parts, their life depends on maintenance. After each use of this starter, it is essential to recharge the
internal battery. Storage in places with high temperatures greatly reduces the battery charge. In the case of prolonged
non-use, it is strongly recommended to recharge the battery before use. In general, we recommend leaving the
product plugged in continuously to maintain the battery at its best performance.
This product is equipped with one high performance battery. If the maintenance instructions are not followed, the
battery can deteriorate irreversibly over time.
For this reason, the GYSPACK PRO battery is excluded from the warranty.
14
STARTPACK 12.24 CI / PRO 12.24 CI
6 A
off
flashing on
1 ) Analysis
2 ) Recovery
3 ) Sulphation test
4 ) Desulphation
5 ) Charge
6 ) Absorption
7 ) Floating
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Startpack pro 12.24 ci068155

Tabla de contenido