TROUBLESHOOTING

Troubleshooting
The device beeps and the red LED
is on.
The «RECHARGE!»
indicator
flashes.
Sparks appear when the clamps
make contact with the battery
terminals.
The unit can no longer start the
vehicle and the red light is off.
Only the indicator
is lit.
Indicator
is lit and indicator
flashes 3 times in succession.
Indicator
flashes alternately with
indicator
.
Indicator
flashes 3 times in suc-
cession.
The Startpack is connected to the
mains.
No indicator is on.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
STARTPACK 12.24 CI / PRO 12.24 CI
Causes
The device detects a polarity reversal. Check the battery polarity. Red clamp to the po-
At some point, the voltage of the
internal battery has dropped below
12.7 V following a start or a heavy
consumption.
The switch is on 12V or 24V.
The battery switch is ON and/or
the selector switch is on 12 V or
24 V.
The voltage selector switch is in the
wrong position.
Polarity reversal.
The voltage of the internal batteries
is very low. It may be that the inter-
nal batteries are damaged.
The fuse has melted.
The battery is heavily discharged
(<4V).
The switch is not connected to 12 V. Connect correctly the voltage switch to 12V
Charging time is too long.
The battery voltage is too high (>
16 V).
Thermal protection of the charger.
No mains voltage.
The EON card is out of order
The switch is not connected to 12 V. Connect correctly the voltage switch to 12V
Solutions
sitive battery terminal (+) and the black clamp
to the negative (-).
Charge the device after each use. The red light
goes out.
Switch the machine off before connecting the
clamps to the battery.
Before connecting the clamps to the battery,
set the battery switch to OFF, disconnect the
voltage selector.
Check that the vehicle voltage corresponds to
the selected voltage.
Check the battery polarity.
Put the device on charge in order to attempt to
recover the battery.
Check and replace the fuse.
Internal batteries require replacing
Internal batteries require replacing
Set the voltage selector switch to "12 V".
The charger is overheating because the room
temperature is high. The charger restarts the
charge automatically once the temperature falls
sufficiently.
Check for 230V voltage.
Contact the after-sales service.