GYS STARTPACK 12.24 CI Manual Del Usuario página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
Translation of the original instructions
STARTPACK PRO 12.24 CI
1
3
5
Product
STARTPACK PRO 12.24
Regardless of how the STARTPACK PRO 12.24 is being used, always replace both batteries at the same
time.
To replace the batteries :
Disconnect the booster from the mains beforehand.
Unscrew the back shell ( 1 - 8 screws) and remove it.
Once the back panel is removed, the batteries are visible, one on top of the other (see picture).
The batteries are maintained by a partition (striped area
the - terminal and at the + terminal.
Start with the top battery. First completely unscrew the retaining wall 2 , then unscrew the two nuts on the - and
+ side of the battery 3 and remove it.
Once the first battery is removed, make sure to insulate the terminals to prevent any short circuit.
Then, do the same with the bottom battery. Unscrew the partition 4 , then unscrew the two nuts used to connect
the battery to the STARTPACK 5 and remove the battery.
When putting new batteries, make sure to match the polarities of both batteries and STARTPACK
PRO 12.24 CI. Reassemble the batteries in the following order:
Reposition and tighten slightly the bottom partition 4 . Then insert the battery, screw it back on 5 and tighten
the partition completely. Do the same with the bottom battery. Position the partition first and tighten lightly 2 ,
insert the battery, screw it back 3 and tighten the partition completely. Finally screw the back shell 1 back on.
STARTPACK 12.24 CI / PRO 12.24 CI
2
4
Battery
Type
PC950
Lead acid battery
Voltage (V)
Capacity (Ah)
2 x 12
2 x 30
) and connected to the STARTPACK at two points: at
EN
3
5
Dimensions (cm)
Battery ref
25 x 9,7 x 15,6
53135
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Startpack pro 12.24 ci068155

Tabla de contenido