Moving And Storing The Unit; Troubleshooting - Klarstein 10028187 Manual De Instrucciones

Ocultar thumbs Ver también para 10028187:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Cleaning of the handle position and remote control storage area
Take the remote control out of the storage area in
the direction shown by the arrow. Clean the handle
position and remote control storage area of this unit
with wringed wet soft cloth. Do not drip water into
the unit. If the remote control needs to be put back
into the remote control storage area, put it back into
the storage area in the reverse direction of removal.

Moving and Storing the Unit

To handle or move the unit, hold the top
of the air outlet of the front shell with one
hand and the handle position at the top of
the back shell with another hand, and leave
the unit in upright position.
IMPORTANT: Do not hold the horizontal
louvre by hand. Leave the unit in the up-
right position when handling or moving it. If
the remote control is in the position of the
handle, take out the remote control.
End of Season Storage
• Screw off the drain cap, unplug the water plug and drain the water in the water tray to another
vessel that holds water. The tilt angle of the unit shall not be greater than 30 degrees.
• Start the unit, turn the mode to the low fan speed state of the air supply mode, keep this state for
half a day and dry the interior of the unit to prevent mold.
• Turn off the unit, unplug the power plug, wrap the power cord around the wire-winding post, insert
the plug into the universal jack at the back shell of the unit; install the water plug and drain cap.
• Remove the heat exhaust hose assembly and keep it properly.
• Pack the air-conditioner properly with soft plastic bag, put the unit in a dry place & take appropri-
ate dust-proof measures, and keep the unit out of the reach of children.
• Take out the batteries of the remote control and keep it properly.
Certain problems can be solved easily without calling out an engineer. Before conacting your local
Service Centre, please carry out the checks listed underneath. If you are unable to identify or solve
the problem, contact your local Service centre.
Problem
Cause
The air-
No power.
conditioner
does not
Full water indicator illuminates.
work
Ambient temperature too low ?
The room temperature is lower than the
set temperature in the cooling mode.
Bad cooling
There is direct sunlight.
or heating
The doors and windows are open, the
effects
room is crowded or there are other heat
sources in the cooling mode.

Troubleshooting

Remedy
Connect the unit to a live socket and
turn it on.
Drain the water stored in the unit.
It is recommended that this unit be
operated at 10-35°C.
Change the set temperature.
Draw the curtain on.
Close the door and window and add new
air-conditioners.
18