Technical Data - Rockwell Automation Allen-Bradley 931H-A1A1N-IP Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6.

Technical Data

Input
Input voltage
Operating current
Voltage drop
Input overload capacity
Output
Load
Response time
(to reach 99% program value)
Residual ripple
General data
Chopper frequency
Transmission errors
Temperature effect
Test voltage
Input / output
2)
EMC
Ambient temperature
Operation
Storage
1)
Medium temperature coefficient in the specified
operating temperature range (-25 °C ... +60 °C)
2)
Valid for 4 ... 20 mA; minor deviations are possible
during interferences.
0 ... 20 mA
max. 15 V
< 100 μA
2.5 ... 3 V (at 20 mA)
max. 50 mA, 15 V
0 ... 20 mA, max. 10 V
500 Ω
approx. 5 ms for a load of 500 Ω
< 10 mV
approx. 200 kHz
< 0.1 % of end value + 0.05 % of
measured value / 100 Ω load
1)
50 ppm/K from measured value
for a load of 0 Ω
510 V AC, 50 Hz
EMC directive
EN 61 326
EN 61 326/A1
-25 °C ... +60 °C
-40 °C ... +85 °C
eff