PROBLEM
Machine does not run.
Machine has little or no suction.
Squeegee has poor pick up.
10
CAUSE
ON/OFF switch is OFF.
Vacuum not plugged to wall outlet.
Faulty ON/OFF switch.
Faulty Power Cord
Faulty wiring.
Building circuit breaker tripped.
Vacuum motor overheated.
Faulty vacuum motor.
Hose is clogged
Holes in hose.
Intake is clogged.
Drain hose knob is loose or open.
Lid is not securely latched.
Worn gasket which is leaking air.
Recovery tank or bag is full.
Debris is wedged under squeegee
blade.
Squeegee blades are worn.
Vacuum hose on squeegee mount is
loose.
Recovery tank is full.
Home
Find... Go To..
SOLUTION
Turn switch to ON.
Plug power cord to wall outlet.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Reset circuit breaker.
Find obstruction. Cool motor for 20
minutes.
Contact Service Center.
Clear hose.
Replace hose.
Remove hose and clear obstruction.
Tighten drain knob.
Latch both latches down securely.
Inspect all gaskets, replace if
necessary.
Empty tank or bag.
Wipe off squeegee blade.
Replace squeegee blades.
Push vacuum hose on securely.
Empty tank.