Equipment failures
Malfunction
Motor does not start up
Motor hums but does not start
up
Machine
starts
up,
but
becomes blocked at low load
and may switch off auto-
matically
Guarantee
Please observe the enclosed terms of guarantee.
Possible cause
⇒ no mains voltage
⇒ defective cable
⇒ thermostat is triggered
− motor overload
− motor not getting enough air owing to
clogged ventilation apertures
⇒ blocked crown gear
⇒ defective condenser
⇒ extension cord is too long or its cross-section
is too small
⇒ socket is too far from mains connection and
the connecting wire's cross section is too small
Remedy
⇒ check fuse protection
⇒ have checked or replaced (electrician)
⇒ allow motor to cool and then find and eliminate
reason:
whatever caused the thermostat to respond
⇒ switch off machine, pull plug and clean or
replace the crown gear segments
⇒ send machine to manufacturer or a company
designated by the manufacturer for repairs
⇒ extension cord must be at least 1.5 mm² for a
maximum length of 25 m; the cross-section of
longer cables must be at least 2.5 mm²
19