Manual Start
The generator is equipped with a manual
recoil starter which may be used if the battery
is discharged.
NOTE: The switch must be in the RUN/ON
position. Use one of the generator's recepta-
cle outlets along with the included battery
charger to charge the battery while the gener-
ator is running.
To start manually:
1. Firmly grasp the recoil handle and pull
slowly until increased resistance is felt.
2. Pull rapidly up and away to start engine.
3. Follow the same choke sequence.
NOTE: If engine fires, but does not continue to
run, move choke lever to Full Choke and
repeat starting instructions.
IMPORTANT NOTE: Do not overload gener-
ator or individual panel receptacles. These
outlets are overload protected with push-
to-reset circuit breakers. If amperage rat-
ing of any circuit breaker is exceeded, that
breaker opens and electrical output to that
receptacle is lost. Read
Limits
carefully.
Generator Shut Down
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Shut off all loads and unplug electrical
loads from generator panel receptacles.
2. Let engine run at no-load for several min-
utes to stabilize internal temperatures of
engine and generator.
3. Move Run/Stop switch to Stop.
4. Close fuel valve.
NOTE: Under normal conditions, close fuel
valve and allow generator to run carburetor
bowl out of fuel. For emergencies, switch to
Stop.
Low Oil Level Shutdown System
The engine is equipped with a low oil level
sensor to shut down the engine automatically
when the oil level drops below a specified
level. The engine will not run until the oil has
been filled to the proper level.
IMPORTANT NOTE: Verify proper engine oil
and fuel levels before use.
Owner's Manual for Portable Generator
Know Generator
CAUTION
Charging the Battery (electric
start units only)
NOTE: The battery shipped with the generator
has been fully charged. A battery may lose
some of its charge when not in use for pro-
longed periods of time. If the battery is unable
to crank the engine, plug in the 12V charger
included in the accessory box. RUNNING
THE GENERATOR DOES NOT CHARGE
THE BATTERY.
Use battery charger plug to keep the battery
charged and ready for use. Battery charging
should be done in a dry location.
1. Plug charger into Battery Charger Input
jack, located on the control panel. See
ure
charger into 120 Volt AC wall outlet.
2. Unplug battery charger from wall outlet
and control panel jack when generator is
to be in use.
(000136)
Figure 3-4. Battery Charger Input Jack
Environmental Hazard. Always recycle batteries at an
official recycling center in accordance with all local
laws and regulations. Failure to do so could result in
environmental damage, death, or serious injury.
WARNING
Explosion. Batteries emit explosive gases while
charging. Keep fire and spark away. Wear protective
gear when working with batteries. Failure to do so
could result in death or serious injury.
WARNING
Risk of burns. Batteries contain sulfuric acid and can
cause severe chemical burns. Wear protective gear
when working with batteries. Failure to do so could
result in death or serious injury.
3-4. Plug wall receptacle end of battery
BATTERY
CHARGER
INPUT
WARNING
(000137a)
(000138a)
Fig-
000423
(000228)
15