*Sump Pump
*Table Saw (10")
Television
Toaster
Weed Trimmer
* Allow 3 times the listed watts for starting these
devices.

Transporting/Tipping of the Unit

Do not operate, store or transport the unit at
an angle greater than 15 degrees.
.

Starting Pull Start Engines

Recoil Hazard. Recoil could retract unexpectedly.
Kickback could result in death or serious injury.
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Unplug all electrical loads from the unit's
receptacles before starting engine.
2. Place generator on a level surface.
3. See
Figure
3-2. Open the fuel shut-off
valve (A).
.
ON
OFF
Figure 3-2.Fuel Shut-off Valve
4. Turn engine RUN/STOP/START switch to
RUN/ON (manual start only). See
2-2.
5. Slide engine choke (C) to Full Choke posi-
tion (left). See
Figure
14
800 to 1050
1750 to 2000
200 to 500
1000 to 1650
WARNING
CAUTION
A
000208
3-3.
500
6. Firmly grasp recoil handle and pull slowly
until increased resistance is felt. Pull rap-
idly up and away.
7. When engine starts, move choke knob to
1/2-choke position until engine runs
smoothly, then fully into RUN position. If
engine falters, move choke back to 1/2-
choke position until engine runs smoothly,
then to RUN position.
NOTE: If engine fires, but does not continue to
run, move choke lever to Full Choke and
repeat starting instructions.
IMPORTANT NOTE: Do not overload the
generator. Also, do not overload individual
panel receptacles. These outlets are pro-
(000183)
tected against overload with push-to-reset-
type circuit breakers. If amperage rating of
any circuit breaker is exceeded, that
breaker opens and electrical output to that
receptacle is lost. Read
Limits
(000136)

Starting Electric Start Engines

Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Unplug all electrical loads from the unit's
receptacles before starting the engine.
2. Place generator on a level surface.
3. Open the fuel shut-off valve. See
2.
4. Move engine choke knob outward to Full
Choke. See
5. Press and hold RUN/STOP/START switch
in the START position. When engine
starts, release the switch to the RUN posi-
tion.
6. When engine starts, move choke knob to
1/2 choke position until engine runs
smoothly, then fully to RUN position. If
Figure
engine falters, move choke knob back to
1/2 choke position until engine runs
smoothly, then move to RUN position.
C
Figure 3-3.Choke Position
carefully.
CAUTION
Figure
3-3.
Owner's Manual for Portable Generator
000209
Know Generator
(000136)
Figure 3-