Owner's Manual
Model:
D4, E4, F4
+ Models:
D4+, E4+, F4+
Validated Models:
D4-V, E4-V, F4-V
D4-V+, E4-V+, F4-V+
Powered by
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. (+1) 519.763.1032 • f. (+1) 800.265.7246 (US and Canada only)
t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069
e-mail: info@viqua.com
www.viqua.com
603037_RevO

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Viqua D4

  • Página 1 Owner’s Manual Model: D4, E4, F4 + Models: D4+, E4+, F4+ Validated Models: D4-V, E4-V, F4-V D4-V+, E4-V+, F4-V+ Powered by 425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1 t. (+1) 519.763.1032 • f. (+1) 800.265.7246 (US and Canada only) t.
  • Página 2 • VIQUA replacement lamps undergo rigorous performance testing and strict quality control processes to ensure that the safety and performance certifications of the original equipment are not compromised. So, you can see that it's simply not worth the risk! Insist on genuine VIQUA replacement lamps.
  • Página 3: Safety Information

    Safety Information Section 1 Safety Information Please read this entire manual before operating this equipment. Pay attention to all danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to the equipment. Make sure that the protection provided by this equipment is not impaired.
  • Página 4: Water Chemistry

    Safety Information WA R N I N G During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system.
  • Página 5: General Information

    Reference card 603069 Used for all models Junction box (optional) 650705 Used for all models 602805 D4, D4+, D4-V, D4-V+ Lamp (includes O-rings) 602806 E4, E4+, E4-V, E4-V+ 602807 F4, F4+, F4-V, F4-V+ Sleeve bolt 602665...
  • Página 6 650717-001 D4 (3/4”) Solenoid valve kit (optional) (includes junction box) 650717-002 E4, F4, F4+ (1") 650537 D4, D4+, D4-V, D4-V+ (3/4”) CoolTouch valve (optional) 650538 E4, E4+, E4-V, E4-V+, F4+(1") F4-V (1"), F4-V+ (1") O-ring 002026 Used for all models To find out what model you have, look at the label on the side of the controller as depicted below: "A"...
  • Página 7 General Information 2.1 Dimensions and Layout OUTLET Clearance for lamp removal 48” ( 122cm ) To Drain Ø INLET Figure 3 System - Dimension and Layouts Item Description Function Sample valve Allows for sampling of raw water. Shut-off valve Required to allow maintenance of pre-treatment equipment. Refer to Section 1.3.
  • Página 8 Power source Circuit Interrupter (GFCI). NOTE: to protect the controller, a UL1449 certified (or equivalent) transient voltage surge suppressor is required. Ø Model A (maximum) D (maximum) D4/D4+/D4-V/D4-V+ 20.5" (52cm) 4" (10cm) 72" (183cm) 8.5" (22cm) 6" (15cm) 54" (137cm) E4/E4+/E4-V/E4-V+ 30"...
  • Página 9 Installation • Insert the reference card • Connect power cord to • Install the sleeve bolt with 2 • Install the lamp into sleeve between controller and controller. new O-rings to the sleeve. and hand tighten. mounting bracket. • DO NOT connect the power Note: Over tightening will cord to the GFCI outlet at this Note: Outlet must be...
  • Página 10 Installation 3.2 Disinfection Procedure UV disinfection is a physical disinfection process and does not add any potentially harmful chemicals to the water. As UV does not provide a disinfection residual, it is imperative that the entire distribution system located after the UV be chemically disinfected to ensure that the plumbing system is free from any bacteriological contaminants.
  • Página 11: Control Panel

    Operation Section 4 Operation 4.1 Control Panel Figure 4 Control Panel Buttons and Display Feature Description Function Lamp timer display Counts down from 365 days to show time for annual lamp replacement. Lamp timer reset After installing a new lamp, press and hold for five seconds to reset Lamp timer to 365. •...
  • Página 12 Maintenance Section 5 Maintenance WA R N I N G • Always disconnect power before performing any work on the disinfection system. • Always shut-off water flow and release water pressure before servicing. • Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present. •...
  • Página 13 Maintenance • Insert and secure the • Restore power. • Align connections by the • Insert the safety cap. lamp/sleeve assembly. rotating ring clamp and install • If new lamp was inserted, the lamp plug. press and hold lamp timer Note: Over tightening will reset button for 5 seconds.
  • Página 14 Maintenance • Reinstall the UV sensor. • When service is complete, assemble the prerequisites in the reverse order of disassembly. Notes: 1) After replacing the UV lamp or quartz sleeve perform the disinfection procedure, refer to Section 3.2. 2) If the system is put on a temporary by-pass or if it becomes contaminated after the disinfection system, it is necessary to complete the disinfection procedure, refer to Section 3.2.
  • Página 15: Troubleshooting

    Troubleshooting Section 6 Troubleshooting Symptom Possible Cause Possible Solution GFCI and/or breaker tripped Reset GFCI and/or breaker No power Transient voltage surge suppressor (TVSS) damaged Replace TVSS Controller damaged Replace controller and use a TVSS Clean and dry lamp pins and lamp plug, check unit for leaks Connection between lamp and lamp plug is wet GFCI or breaker repeatedly or condensation...
  • Página 16 Flushing the UV system alleviates this condition until the softener goes through another regeneration cycle. In the longer term, the softener's settings must be modified. To flush the UV system, disinfect the water lines. Refer to Section 3.2. Refer to Section 4.1. Contact VIQUA or your water treatment dealer for a test of the UVT of the water.
  • Página 17 Vertical or horizontal* Flow Restrictor NSF Certification NSF Standard 55 Class B Rated service life of lamp 1 year 1 year UV System Certification D4/D4+ E4/E4+ F4/F4+ Model D4-V/D4-V+ E4-V/E4-V+ F4-V/F4-V+ Maximum rated flow at dose of 16 mJ/cm 23 gpm (87 lpm) (5.22 m /hr) 42 gpm (160 lpm) (9.54 m...
  • Página 18 VIQUA warrants the electrical (controller) and hardware components to be free from defects in material and workmanship for a period of three (3) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty.
  • Página 20 (+1) 519.763.1032 • f. (+1) 800.265.7246 (solo EE. UU. y Canadá) t. (+31) 73 747 0144 (Europe seulement) • f. (+1) 519.763.5069 t. (+31) 73 747 0144 (solo Europa) • f. (+1) 519.763.5069 Courriel : info@viqua.com correo electrónico: info@viqua.com www.viqua.com...