Priming Pump - Hayward HCP5000 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

required and other recommended are located, which generally will have:
1. A system pole disconnection (for all phases) with opening of at least 3mm
contact separation.
2. Devices circuit protection and overload engine
3. High sensitivity RCD, 30mA
-
The electrical characteristics of protective devices and regulation, will agree to protect
motors under the intended service conditions, and with the instructions provided by the
manufacturer listed on the nameplate.
-
The bridges that interconnect the motor windings should be correctly positioned.
(According to the following scheme and to what is indicated on the nameplate of the
motor)
-
The input and output wires to the terminal box will be connected by means of a cable
gland to ensure tightness, lack of moisture and dirt. The wires will be equipped with the
suitable terminals to allow a secure connection to the terminal box.
START UP

6.1 Priming Pump

Before starting up the pump must be primed with water. The water cools and
20

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hcp5200

Tabla de contenido