Installation location
Before installing the device, plan its location and orientation relative to other devices and equipment. Switches can
be mounted in a standard 19-inch equipment rack that meets EIA-310D standards, or on a flat surface. Be sure to
follow the guidelines below when choosing a location.
The site should meet the following requirements:
Maintain temperatures within 0 to 40 ο C (32 to 104 ο F) and humidity levels within 5% to 95%, non-condensing.
Allow a minimum of 7.62 cm (3 in.) of space between the sides and the back of the device and walls or other
obstructions for proper air flow.
Allow at least 3 in. of space at the front and back of the device for the twisted-pair, fiber-optic, and power
cabling.
Be accessible for installing, cabling and maintaining the devices.
Allow the status LEDs to be clearly visible.
Allow for twisted-pair cable to be always routed away from power lines, fluorescent lighting fixtures and other
sources of electrical interference, such as radios and transmitters.
Allow for the unit to be connected to a separate grounded power outlet that provides 110 to 240 VAC, 50 to 60
Hz, is within 2 m (6.6 feet) of each device and is powered from an independent circuit breaker. As with any
equipment, a filter or surge suppressor is recommended.

General precautions

CAUTION
All fiber-optic interfaces use Class 1 lasers.
CAUTION
Do not install the device in an environment where the operating ambient temperature might
exceed 40 ο C (104 ο F).
CAUTION
Make sure the air flow around the front and sides of the device is not restricted.
CAUTION
Never leave tools inside the device.
PowerConnect B-Series FCX/FCXS Getting Started Guide
53-1002049-01