ﺍﻟﺠﺰء
D301205X012
2
ﺻﻔﺤﺔ
MVS205
. ﺍﻓﺤﺺ ﺟﻤﻴﻊ ﻣﺴﺎﻓﺎﺕ
ﺍﻟﺨﻠﻮﺹ ﻋﻨﺪ ﺍﺧﺘﻴﺎﺭ ﻣﻮﻗﻊ ﺍﻟﺘﺮﻛﻴﺐ. ﻭﺍﺣﺮﺹ ﻋﻠﻰ ﺗﻮﻓﻴﺮ
.ﺍﻟﺨﻠﻮﺹ ﺍﻟﻜﺎﻓﻲ ﻟﻠﺘﻮﺻﻴﻼﺕ ﺍﻟﺴﻠﻜﻴﺔ ﻭﺍﻟﺨﺪﻣﺔ
MVS205
ﺃﺳﻔﻞ ﻫﻴﻜﻞ ﻣﺴﺘﺸﻌﺮ
ﺍﻟﺘﺮﻛﻴﺐ ﻋﻠﻰ ﺣﺎﻣﻞ ﺃﻧﺎﺑﻴﺐ ﺃﻭ ﺣﺎﺋﻂ ﺃﻭ ﻟﻮﺣﺔ ﺃﻭ ﺑﺼﻨﺎﺑﻴﺮ ﺍﻟﺤﺎﻓﺔ
.ﺃﻭ ﺻﻤﺎﻡ ﻣﺘﻌﺪﺩ ﺍﻟﺸﻌﺐ
ﺍﻟﺨﺎﺻﺔ ﺑﻤﺠﻤﻮﻋﺔ ﺍﻟﻔﺘﺤﺎﺕ ﺍﻟﻤﺪﻣﺠﺔ
ﻋﻠﻰ ﻟﻮﺣﺔ ﺃﻭ ﺃﻧﺒﻮﺏ
MVS205
ﺍﻟﺸﻜﻞ
( ﺑﺎﺳﺘﺨﺪﺍﻡ
، ﻭ
5
4
ﻁﺎﻗﻢ ﺍﻟﻜﺘﻴﻔﺔ ﺍﻻﺧﺘﻴﺎﺭﻱ، ﻭﺍﻟﺬﻱ ﻳﺸﻤﻞ ﻛﺘﻴﻔﺔ ﻋﻠﻰ ﺷﻜﻞ
ﻭﻣﺸﺒﻚ ﺃﻧﺎﺑﻴﺐ. ﻳﺘﻢ ﺗﺜﺒﻴﺖ ﻁﺎﻗﻢ ﺍﻟﻜﺘﻴﻔﺔ ﺑﺤﺎﻓﺔ
.ﻋﻠﻰ ﻣﻮﺻﻞ ﺍﻟﻀﻐﻂ
ﺏ
ﺝ
NPT
ﺑﻮﺻﺔ
½
ﺑﺤﺠﻢ
ﻣﺪﺧﻞ ﻟﻠﺘﻮﺻﻴﻼﺕ ﺍﻟﺴﻠﻜﻴﺔ ﻟﻠﻤﺠﺎﻝ
ﻣﻮﻗﻊ ﺍﻟﻌﺮﻭﺓ ﺍﻷﺭﺿﻴﺔ ﺍﻟﺨﺎﺭﺟﻴﺔ
MVS205
ﺍﻟﻤﺴﺘﺸﻌﺮ ﻣﺘﻌﺪﺩ ﺍﻟﻤﺘﻐﻴﺮﺍﺕ
NPT
18
ﺑﺤﺠﻢ
ﻭﺻﻠﺔ
ﻳﺘﻢ ﻧﻘﻞ ﻣﺪﺧﻼﺕ ﺿﻐﻂ ﺍﻟﻌﻤﻠﻴﺔ ﺇﻟﻰ
.ﺇﻟﻰ ﺻﻤﺎﻡ ﺗﺪﺧﻞ ﻣﺘﻌﺪﺩ ﺍﻟﺸﻌﺐ
ﺃﻭ
MVS205
ﻣﺒﺎﺷﺮﺓ ﺑﺼﻨﺎﺑﻴﺮ ﺍﻟﺤﺎﻓﺔ
ﺑﺎﺳﺘﺨﺪﺍﻡ ﺻﻤﺎﻡ ﻣﺘﻌﺪﺩ ﺍﻟﺸﻌﺐ ﺃﻭ ﻣﺠﻤﻮﻋﺔ ﻓﺘﺤﺎﺕ ﻣﺪﻣﺠﺔ
ﺍﺳﺘﺨﺪﻡ ﻣﺪﺧﻼﺕ ﺍﻟﺘﻮﺻﻴﻼﺕ ﺍﻟﺴﻠﻜﻴﺔ ﻟﻠﺤﻘﻞ ﻹﺩﺧﺎﻝ ﺍﻷﺳﻼﻙ ﻓﻲ
MVS
. ﻳﺠﺐ ﺃﻥ ﺗﻈﻞ ﻣﻘﺎﺑﺲ ﺍﻷﻧﺒﻮﺏ
ﻣﻜﺎﻧﻬﺎ ﻋﻠﻰ ﺍﻟﻤﺪﺧﻼﺕ ﻏﻴﺮ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻟﻠﺤﻔﺎﻅ ﻋﻠﻰ
.ﺳﻼﻣﺔ ﺍﻟﺤﺎﻭﻳﺔ ﻟﻤﻘﺎﻭﻣﺔ ﺍﻻﺷﺘﻌﺎﻝ
ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺟﻬﺎﺯ ﻣﺪﺧﻼﺕ ﺍﻟﻜﺎﺑﻞ ﻣﻌﺘﻤ ﺪ ًﺍ ﻣﻦ ﺣﻴﺚ ﻧﻮﻉ ﺍﻟﺤﺎﻭﻳﺔ
، ﺍﻟﻤﻼﺋﻤﺔ ﻟﻈﺮﻭﻑ
"
" ﺩ
ﺍﻟﻤﻀﺎﺩﺓ ﻟﻼﺷﺘﻌﺎﻝ ﻟﻠﺤﻤﺎﻳﺔ ﻣﻦ ﺍﻻﻧﻔﺠﺎﺭ
ﺍﻻﺳﺘﺨﺪﺍﻡ ﻭﺍﻟﻤﺮ ﻛ ّ ﺒﺔ ﻋﻠﻰ ﻧﺤﻮ ﺻﺤﻴﺢ. ﺑﺎﻟﻨﺴﺒﺔ ﻟﺪﺭﺟﺎﺕ ﺍﻟﺤ
ﺮﺍﺭﺓ
ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ، ﺍﺳﺘﺨﺪﻡ ﺍﻟﻜﺎﺑﻼﺕ ﻭﺟﻠﺒﺎﺕ
90
.ﻣﺌﻮﻳﺔ
ﺍﻟﻜﺎﺑﻼﺕ ﺍﻟﻤﻨﺎﺳﺒﺔ ﻟﺪﺭﺟﺔ ﺣﺮﺍﺭﺓ ﻻ ﺗﻘﻞ ﻋﻦ
ﺣﺪﺩ ﻣﻜﺎ ﻧ ً ﺎ ﻣﻨﺎﺳ ﺒ ًﺎ
2 .
ﻟﻤﺴﺘﺸﻌﺮ
Coplanar™
3 .
ﺗﺘﻴﺢ ﺣﺎﻓﺔ
ﻳﻤﻜﻦ ﺗﺮﻛﻴﺐ
ﺍﻟﺸﻜﻞ
ﺍﻟﺸﻜﻞ
،
)ﺍﻧﻈﺮ
3
ﺣﺮﻑ
L
coplanar
ﺃ
ﺩ
ﻫـ
ﻣﺸﺒﻚ ﺍﻟﻐﻄﺎء
ﺃ
ﺭﺃﺱ ﺍﻹﻟﻜﺘﺮﻭﻧﻴﺎﺕ
ﺏ
ﻣﻮﺻﻞ ﺍﻟﻀﻐﻂ
ﺝ
14
ﺩ
ﻫـ
2 .
ﺍﻟﺸﻜﻞ
4 .
MVS205
ﺑﻮﺻﺔ ﺃﺳﻔﻞ
¼
ﻭﻳﻤﻜﻨﻚ ﺃﻳ ﻀ ً ﺎ ﺗﺮﻛﻴﺐ
.()ﻏﻴﺮ ﻣﻮ ﺿ ّﺢ
5 .
ﺭﺃﺱ ﺇﻟﻜﺘﺮﻭﻧﻴﺎﺕ ﻣﺴﺘﺸﻌﺮ
ﺍﻟﻤﻌﺪﻧﻲ ﻓﻲ
ﻭﺻﻠﺔ ﺍﻟﻜﺎﺑﻞ
70
ﺍﻟﻤﺤﻴﻄﺔ ﺍﻟﺘﻲ ﺗﺘﺠﺎﻭﺯ
MVS205
–
ﺇﺭﺷﺎﺩﺍﺕ ﺍﻻﺳﺘﺨﺪﺍﻡ ﺍﻵﻣﻦ
ﺍﻟﻤﻮﺍﺻﻔﺎﺕ
30
8
75
ﻓﻮﻟﺖ
ﺇﻟﻰ
:ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ
ﺩﺧﻞ ﻋﻨﺪ ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ
.ﻣﻴﺠﺎﻭﺍﺕ ﻓﻲ ﺍﻟﻤﺘﻮﺳﻂ
30
،ﻓﻮﻟﺖ ﺗﻴﺎﺭ ﻣﺴﺘﻤﺮ
ﺇﻟﻰ
ROC/FloBoss
.
ﻣﺰﻭﺩ ﻋﻦ ﻁﺮﻳﻖ
75
40
.ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ
ﺇﻟﻰ
85
.ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ
ﻟﻰ ﺇ
99
.ﺩﻭﻥ ﺗﻜﺎﺛﻒ
،
%
ﺇﻟﻰ
IEC 61326
ﺍﻷﺟﻬﺰﺓ
ﺗﻠﺒﻲ ﻣﺘﻄﻠﺒﺎﺕ ﻣﻌﻴﺎﺭ
.ﺍﻟﻜﻬﺮﺑﻴﺔ ﻟﻼﺳﺘﺨﺪﺍﻡ ﻓﻲ ﺍﻟﻤﻮﺍﻗﻊ ﺍﻟﺼﻨﺎﻋﻴﺔ
EN 55022
ﺍﻟﻔﺌﺔ ﺏ ﻭﺍﻟﻤﻌﻴﺎﺭ
.ﻟﻸﺟﻬﺰﺓ ﺍﻟﺮﻗﻤﻴﺔ
:ﺗﻢ ﺍﻟﺘﻘﻴﻴﻢ ﻭﻓ ﻘ ً ﺎ ﻟﻠﻤﻌﺎﻳﻴﺮ ﺍﻷﻭﺭﻭﺑﻴﺔ ﺍﻟﺘﺎﻟﻴﺔ
MVS205R
.
:ﻋﻼﻣﺎﺕ ﺍﻟﻤﻨﺘﺞ ﻟﻸﻣﺎﻛﻦ ﺍﻟﺨﻄﺮﺓ
ATEX Cert. KEMA 04ATEX2182 X
IEC Cert. IECEx KEM 07.0055X
ﺍﻷﺩﻭﺍﺕ ﺍﻟﺘﺎﻟﻴﺔ ﻻﺯﻣﺔ ﻹﺟﺮﺍء ﺍﻟﺘﺮﻛﻴﺐ ﻭﺍﻟﺼﻴﺎﻧﺔ ﻭﺍﺳﺘﻜﺸﺎﻑ
ﻛﻤﺒﻴﻮﺗﺮ ﺷﺨﺼﻲ ﻳﻌﻤﻞ ﺑﻨﻈﺎﻡ ﺍﻟﺘﺸﻐﻴﻞ
Service Pack 2
Microsoft
(
)ﻣﻊ
Windows 7
.
ROCLINK™ 800
.
.(ﺑﻮﺻﺔ
.(ﺑﻮﺻﺔ
.ﻣﻦ ﺻﻨﺪﻭﻕ ﺍﻟﺸﺤﻦ
ﺍﻟﻄﺎﻗﺔ
0
ﺇﻟﻰ
ﺩﺧﻞ ﻋﻨﺪ ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ
245
،ﺗﻴﺎﺭ ﻣﺴﺘﻤﺮ
8.5
0
40-
:ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ
ﺇﻟﻰ
245
.ﻣﻴﺠﺎﻭﺍﺕ ﻓﻲ ﺍﻟﻤﺘﻮﺳﻂ
ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﺍﻟﺒﻴﺌﻴﺔ
-
:ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺃﺛﻨﺎء ﺍﻟﺘﺸﻐﻴﻞ
50
-
:ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ ﺍﻟﺘﺨﺰﻳﻦ
0
:ﺩﺭﺟﺔ ﺍﻟﺮﻁﻮﺑﺔ ﺃﺛﻨﺎء ﺍﻟﺘﺸﻐﻴﻞ
:ﺍﻟﺤﻤﺎﻳﺔ ﺍﻟﻤﺸﻌﺔ/ﺍﻟ ﻤ ُ ﺪﺍﺭﺓ
ﺗﻠﺒﻲ ﻣﻌﻴﺎﺭ
:ﺍﻻﻧﺒﻌﺎﺛﺎﺕ ﺍﻟﻤﺸﻌﺔ
ICES-003:1997
ﺍﻟﻮﺯﻥ
3.0
ﻛﺠﻢ، ﺑﻤﺎ ﻓﻲ ﺫﻟﻚ ﺍﻟﺮﺃﺱ
ﺍﻟﺘﺼﺪﻳﻘﺎﺕ
ATEX/IECEx
EN 60079—0 (2006)
.
EN 60079—1 (2007)
.
EN 61241—0 (2006)
EN 61241—1 (2004)
EN 60529 (2001)
.
KEMA
ﻛﻄﺮﺍﺯ
ﻣﻌﺘﻤﺪ ﻣﻦ
Ex d IIB T5 (T
=75°C)
.
amb
Ex tD A21 IP66 T85°C
.
II 2 GD.
0081.
:ﺍﻟﻤﺸﻜﻼﺕ ﻭﺣﻠﻬﺎ
®
Windows
®
2000
Windows Vista
ﺃﻭ
ﺃﻭ
ﺑﺮﻧﺎﻣﺞ ﺗﻜﻮﻳﻦ
.(ﻣﻔﻚ ﻓﻴﻠﺒﺲ )ﺑﺮﺃﺱ ﻣﺘﺼﺎﻟﺐ
.ﻣﻔﻚ ﺑﺮﺃﺱ ﻣﺴﻄﺢ
3/8
) ﻣﻔﺘﺎﺡ ﺭﺑﻂ ﺳﺪﺍﺳﻲ
7/16
) ﻣﻔﺘﺎﺡ ﺭﺑﻂ ﺳﺪﺍﺳﻲ
.(ﻣﻢ
3
) ﻣﻔﺘﺎﺡ ﺃﻟﻦ ﺳﺪﺍﺳﻲ
MVS205
1 .
ﺃﺧﺮﺝ ﻣﺴﺘﺸﻌﺮ