20 Post-gas: permits setting and adjustment of the gas flow at
the end of welding.
Minimum off, Maximum 99.9s, Default 2.0s
25 Spot welding: allows you to enable the "spot welding" pro-
cess and establish the welding time.
Minimum 500ms, Maximum 99.9s, Default off
26 Pause point: allows you to enable the "pause point" process
and establish the pause time between one welding opera-
tion and another.
Minimum 500ms, Maximum 99.9s, Default off
92 Reset XP (Professional Mode)
0 Save and quit: allows you to save the changes and quit the
set up.
1 Reset: allows you to reset all the parameters to the default
values.
3 Pre-gas: allows you to set and adjust the gas flow prior to
sparking of the arc.
Permits filling of the torch with gas and preparation of the
environment for welding.
Minimum off, Maximum 99.9s, Default 10ms
4 Soft start: permits adjustment of the wire feed speed in the
phases prior to sparking.
Given as a % of the wire speed set.
Permits sparking at reduced speed, therefore softer and with
fewer splashes.
Minimum 10%, Maximum 100%, Default 50%
5 Motor ramp: allows you to set a gradual transition between
the sparking wire speed and the welding wire speed.
Minimum off, Maximum 1.0s, Default 250ms
18 Burn back: permits adjustment of the wire burn time, pre-
venting sticking at the end of welding.
Permits adjustment of the length.
Permits adjustment of the length of the piece of wire outside
the torch.
Minimum off, Maximum 2.0s, Default 80ms
20 Post-gas: permits setting and adjustment of the gas flow at
the end of welding.
Minimum off, Maximum 99.9s, Default 2.0s
25 Spot welding: allows you to enable the "spot welding" pro-
cess and establish the welding time.
Minimum 500ms, Maximum 99.9s, Default off
26 Pause point: allows you to enable the "pause point" process
and establish the pause time between one welding opera-
tion and another.
Minimum 500ms, Maximum 99.9s, Default off

3.3.2 Alarm codes

01/02
Overtemperature.
05
Secondary short circuit.
08
Wire feed motor blocked.
11
Machine configuration not valid.
14
Welding not possible with the step set.
20
Communication error.
21
Machine not calibrated or loss of data.
28
All manuals and user guides at all-guides.com

3.4 Rear panel

1: power supply cable.
Connects the system to the mains.
2: gas fitting
3: 6x32 2,5A 250V fuse
4: plate specifications

3.5 Sockets panel

1,2: variable inductance output sockets.
A higher inductance provides a "softer" arc with fewer splashes
whereas a lower inductance results in a more reactive arc.
Normally, use 1 together with step 1 on the main switch, 2 on
step 2.
3: torch fitting. Permits connection of the MIG torch.