NOTE: Use the DAP jumper to set the keypad into programming mode in case you forgot the master code.
See "4. The DAP Jumper".
c. Go to a location and program the options. See "6. Programming the Keypad – Summary Chart".
d. Program the options until all options are programmed. Repeat the programming of an option in case of a
wrong entry.
LOCATION 1
...
LOCATION n
e. Exit the programming mode with
B) Single user mode operation – Example
1. Requirements
a. Single user mode
b. Change the factory-set master code 0000 to a personal master code 3289
c. Set user code 1 to 8321
d. Set user code 2 to 6854
e. Set user code 3 to 9270
f. Set output 1 to momentary mode, 1 second
g. Set output 2 to start / stop mode
h. Set output 3 to start / stop mode
i. Set the keypad to lock itself during 15 minutes after 10 successive false codes
2. Programming – Setting the above requirements into the keypad
NOTE: * Entering single user command code 8900 is not necessary if the keypad was already in single
user mode.
Cancel a wrong entry with
HAA9523S
OPTION
OPTION n
. All input information has been saved.
Program mode with factory-set master code
Single user mode*
3289 stored as new personal master code and super user code
8321 stored as user code1 with duress code function for output 1
6854 stored as user code 2 for output 2
9270 stored as user code 3 for output 3
Output 1 set as momentary mode, 1 second
Output 2 set to start / stop mode
Output 3 set to start / stop mode
Keypad set to lock during 15 minutes after 10 successive false
codes
Exit programming mode. All above data stored and ready for use
or wait 10 seconds and retry.