4. The DAP Jumper (Direct Access to Programming)
If the personal master code is forgotten, use the DAP jumper to override the forgotten code permitting direct entry
into programming mode. You are required to apply the following procedure precisely:
1. Disconnect power supply.
2. Displace the DAP jumper from OFF to ON.
3. Reconnect power supply (buzzer is activated).
4. Put the DAP jumper back to OFF position (this done, the buzzer is de-activated).
5. The Keypad is in programming mode and ready to receive your new programming data.
6. Enter a new 4-digit master code at location 0 in case you have forgotten the old master code.
7. Enter the new programming data starting from Section B) in the summary chart shown below.
5. The Factory-Set Master Code – Important Note
When programming for the first time, the master code 0000 shall be used. In all cases, program a new master code
to invalidate the old master code and to ensure security.
6. Programming the Keypad – Summary Chart
A) Use the factory-set master code entry in programming -- When starting for first time only
Entry of code
B) Set the system to single or multi-user mode and refresh the system – Installer programming
Entry of code
C) Record the personal master code and user codes – User programming
1. Single user – Digits may be repeated
Locations
Entry of codes
4 digits, fixed
4 digits, fixed
4 digits, fixed
4 digits, fixed
2. Multi-user – Digits may be repeated
Locations
User number
HAA9523S
Validation
Comments
Enter in programming mode by factory set master code
Validation
Comments
Set the system to single user mode, clear all previously stored
data and refresh system
Set the system to multi-user mode, clear all previously stored
data and refresh system
Validation
Entry of codes
4 to 8 digits
00 to 99
4 to 8 digits
Comments
Personal master code and super user code
User code 1 for output 1 with duress code function
User code 2 for output 2
User code 3 for output 3
Validation Comments
Personal master code and super user
code
100 user codes in group 1 for output 1 with
duress code function