Velleman HAA9523S Manual Del Usuario página 9

Control de acceso digital independiente
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

after code entry is required. Once the keypad is programmed in auto entry, the master code and the user
codes MUST consist of the same number of digits. Do not press
Default values
Default Comments
401
Output 1 in 1-second momentary
mode
501
Output 2 in 1-second momentary
mode
601
Output 3 in 1-second momentary
mode
70
After 10 successive false codes, the
keypad locks during 30 seconds
800
Door forced-open alarm disabled
NOTE: * All default values in multi-user and single user mode are exactly the same except the user code entry
mode.
Code entry limitation in multi-user mode due to duress code
The system comes with duress function for user code 1 in single user mode and all the user codes of group 1 in
multi-user mode. The duress code is automatically set by the system by taking the first digit of the user code and
adding or subtracting 2. To prevent other codes falling in the duress code, the first digit of a stored user code +2
or -2 is not allowed as a later user code entry.
Example: User code 56789 was stored in the system. User codes 36789 and 76789 are not allowed.
Set the system to single user mode
Set the system to single user mode with the command code 8900. The system will stay in that mode until it is
refreshed. Make sure the master code is 4 digits long.
MASTER
CODE
Set the system to multi-user mode
Set the system to multi-user mode with the command code 8901. The system will stay in that mode until it is
refreshed.
MASTER
CODE
Refreshing the system
When choosing a different operation mode (see above), the system will reset and clear all values except for the
master code.
NOTE: Make sure the user code and the master code are both 4 digits long when operating in single user mode.
8. Programming and Use of the Keypad – Operation Examples
A) Programming procedures
a. Your HAA9523S is programmed from the keypad. All programmed information is stored in the non-volatile
memory.
b. Set the keypad into programming mode first with the master code and press
HAA9523S
after entering the user code.
Default Comments
811
Output relay activation beep on
820
User code manual entry mode* (multi-
user)
821
User code auto entry mode* (single
user)
831
Pacifier tones on
90
No propped-up alarm
Single user mode enabled. Wait 2-3 seconds after
pressing
until you hear confirmation beeps.
Multi-user mode enabled. Wait 2-3 seconds after
pressing
until you hear confirmation beeps.
9
to validate.
VELLEMAN

Publicidad

Tabla de contenido
loading

Tabla de contenido