outdoor use, however, to extend its life place the sensor in an area
protected from direct weather elements. The best location is 4 to 8
feet(1.2 to 2.4 meters) above the ground with permanent shade and
plenty of fresh air to circulate around the sensor.
Important placement guidelines
The distance between main unit and transmitter should be at least
5~6.5 feet (1.5~2 meters) away from any interfering sources such
as computer monitors or TV sets.
To maximize wireless range, place units away from large metallic
items, thick walls, metal surfaces, or other objects that may limit
wireless communication.
Please do not use other electrical products such as headphones
or speakers operating on the same signal frequency.
Neighbors using electrical devices operating on the same signal
frequency can also cause interference.
Place the main unit more than 1.2 meters away from the power
source for better usage. (including the power source of the prod-
uct itself or any other electrical appliances)
Temperature & Humidity
Indoor temperature display range :-10 ° C~50 ° C (14 ° F
~122 ° F).Outdoor temperature range:-40℃~60℃ (-40℉~140℉),
LL.L or HH.H will display when out of range.
Indoor and outdoor humidity range:1%-99%.;for humidity lower
than 1%,the reading will be "1%" ;for humidity higher than
99%,the reading will be "99%".
Accuracy: For temperature between 10℃~30℃,the accuracy
is±1 ℃,if out of this range the accuracy will be±1.5℃; For humidi-
ty between 40-80%RH,the accuracy is±5%RH,if out of this
range,the accuracy will be±8%RH.Temperature resolution is
0.1 ℃(0.1℉).Humidity resolution:1% .