System Advanced Settings
AIRZONE BLUEFACE
Press and hold
SYSTEM PARAMETERS
•
System address. (Not available on systems with BACnet gateway). This allows you to define
the number of the system in your installation.
•
Temperature range. This allows you to select the maximum temperature for heating
mode (19-30°C / 64-86˚F) and minimum temperature for cooling mode (18-26°C / 64-78˚F),
in steps of 1°C. If you want, you can disable any of the modes. By default, the maximum
heating temperature is set to 30°C (86˚F) and the minimum cooling temperature to 18°C(64
˚F).
•
Global Ventilation. This menu allows you to activate/deactivate the fan mode in all zones
when the system is not actively heating or cooling any zones. By default, the global
ventilation is deactivated. When activated, the following settings are used to configure
Global Ventilation:
1.
Every (min). Configure the length of the interval (in minutes) between periods of
ventilation. Configurable from 5 to 40 minutes, in 5 minutes increments (by default, 15
minutes).
2.
Run For (min). Configure the time duration that ventilation is activated (in minutes).
Configurable from 5 to 20 minutes, in 5 minutes increments (by default, 10 minutes).
Note: when global ventilation is activated, a warning message will appear on the screensaver.
•
Type of opening*. This allows you to enable/disable the proportionality of the system
dampers. Proportionality scales the opening or closing of the damper in 4 steps according
to the temperature demand of the zone, adjusting the zone airflow rate. By default, it is set
to All/Nothing.
If you select the Modulating option, select the desired damper and set the REG lever
position, where position I is completely open.
•
Radio channel. This allows you to enable/disable the system's wireless association channel.