Vessel
Select vessel construction material.
* STEEL
Options
CONCRETE
Response Rate
Sets the reaction speed of the device to
measurement changes in the target range.
Response Rate
SLOW
MED
FAST
Use a setting just faster than the maximum vessel filling or vessel emptying rate (whichever is
greater).
Units
Sensor measurement units.
Values
Operation
Operation
LEVEL (1)
*
SPACE (2)
DISTANCE(3)
sensor reference point
(flange face)
High Cal.
Pt.
Distance
Low Cal. Pt.
Page EN-12
Vessel Fill Rate or Empty Rate
per minute
0.1 m/min (0.32 ft/min)
1.0 m/min (3.28 ft/min)
*
10.0 m/min (32.8 ft/min)
m, cm, mm, ft, in
Default: m
Description
Distance from Low Calibration Point to material surface
Distance from High Calibration Point to material surface
Distance from Sensor Reference Point to material surface
Space
Level
SITRANS LR560 (PROFIBUS PA)
Parameter View
Filter Time Constant
Edit mode
600 s
60 s
0 s
A5E32043113