Connecting to a gas source
Only use propane or butane gas bottles with an approved
pressure reduction valve and suitable top part.
Compare the pressure information on the type plate with the
pressure information on the propane or butane gas cylinder.
The device is fitted with a pilot light. The gas supply is interrupted
when the flame goes out.
➤ Position the gas bottle vertically at a distance of at least 1 metre away
from the burner (on the back of the cooler).
➤ Check if the valve on the gas bottle is closed.
Only use approved hose lines (DIN 4815 part 2) with a maximum
length of 1.5 m.
Your connecting hose must be replaced in accordance with
national guidelines.
➤ Connect the hose line to the head of the valve on the gas bottle and the
cooler (3 1, page 4).
Use an open-ended spanner with the appropriate width for this.
➤ Make sure that the hose line
– Is not crushed or kinked
– Is a safe distance from the burner.
➤ Open the valve on the gas bottle.
Never check for leaks with an open flame or near sources of ignition.
➤ Check all connections with a leakage test spray.
There are no leaks if no bubbles form.
➤ Ensure that
– The thermostat control for 220 V – 240 V operation (2 2, page 3) is
in the "0" position
– The battery plug is not connected.
Operating the cooler