Maintenance and servicing
Check moving parts for ease of movement and if necessary lubricate with commercially-available
•
grease.
Check screw connections
•
• Regular tests to be carried out at intervals of at the longest one year by a qualified person.
In the event of damage and particular incidents that could influence the carrying capacity and after
•
repairs an extraordinary testing by a qualified person is to be carried out.
• Before a sight and function check under some circumstances prior cleaning of the handling system may
be necessary. That applies particularly if they are contaminated with materials e.g. dyes and salts from a
previous use.
The test regime for a sight and function test includes fissures, deformities, cracks, damage, wear,
•
corrosion damage and function faults of the handling system.
• As proof that the tests have been carried out, a test list is to be compiled and kept by the operator.
With visible deformities, obvious damage, heavy wear of the screws and screw guides the handling
•
system must not be used until repaired.
Declaration of conformity
Herewith we, the DENIOS AG, Dehmer Straße 58-66, D 32549 Bad Oeynhausen, declare that the product
complies with following guidelines.
Type:
EC Directives
Machinery directive 2006/42/EC
Harmonised standards applied
EN 13155
EN 349
EN ISO 14121
EN 12100 -1,-2
Person responsible for documentation
Mr. Dr. Ing. R. Adenstedt
Head of engineering
Chwytak nożycowy typu HW
115258
EC Declaration of Conformity
Scissors gripper HW
Strona 7 z 12
DENIOS AG, 04.01.2010
Theodor Breucker
- Board of governors -
Wydanie 01/2010