All manuals and user guides at all-guides.com
B
Installation
Attach the two fastening strips to the bottom of the motor body and hang the pump
into the brackets
. The screw clamps of the holders can be inserted in two ver-
sions. The stop screws allow the vertical position of the pump to be adjusted exactly.
When the pump is mounted horizontally (drawing E) the four suction grips are
placed on the fastening strips. Place the pump on the desired position.
C
Start-up
Plug the mains plug to start the pump. Turn the output regulator from min. to max.
to adjust the flow quantity as required.
The pump can be used in or out of water. The pump does not automatically take in
water. Therefore, it must be placed below the level of the water surface if it is used
out of water. Before start-up the water circulation must be set going by suction. If
the pump is used out of water, the pump is used with a hose fitted to the supplied
connection pipe.
C
In this case remove the suction grid from the pump and press the cover out.
1
C
Screw the hos connection on to the pump housing and ensure that the sealing
2
disk is positioned properly.
C
Fit the suction grid on to the pump again.
3
C
Fit the hose on to the hose connections and secure it with the hose straps in-
4
cluded.
D
Care and cleaning
Disconnect the pump from the mains supply. Remove the suction grid from the
pump. Unscrew the four screws and remove the pump housing towards the front.
Remove the complete pump wheel unit (Model 5000) or axle with sleeves (Models
2000 / 3000). Thoroughly wash all the pump parts and clean them with the EHEIM
brush set (order No. 4009570).
Inspect the sealing ring on the motor body for signs of dirt and for correct position.
Renew the sealing ring if it is damaged.
Finally, reassemble all the parts in the reverse sequence.