HC997-999 – MOD. D
Digital multifunction solenoid metering pump
4.3.3
Quantity to dose
The pump doses a desired quantity in the programmed time.
In this functioning mode there are two parameter to set:
Example: Quantity = 350 ml
The pump doses 350ml in 10 minutes.
Press the
Press the
4.3.4
Functioning Cyclical
When the pump is powered, it perform a dosing at the set flow rate for a programmed time
(T
ON
In this functioning mode there are three parameters to set:
ml/min, L/h) – see the settings menu.
Example T
The pump doses 10 seconds every 10 minutes at the 50% of the maximum flow rate.
Press the
Press the
ADSP9000033
All manuals and user guides at all-guides.com
The quantity of the chemical to dose.
Setting from 1 to 2000 ml at steps of 1 ml.
Dose time.
Setting from 1 to 240 minutes at steps of 1 minute.
keys to set the desired values.
key to go at the previous menu.
Perform the calibration of the pump before to use this functioning mode.
The pump automatically calculate the minimum dosing time after set the
quantity.
) every cycle time (T
).
Cycle
T
(working time).
ON
Setting from 0 to 90 minutes at steps of 1 second.
T
(cycle time)
Cycle
Setting from 0 to 24 hours at steps of 1 hour.
Functioning that can be in different units of measurement (%, SPM,
= 10 seconds
ON
keys to set the desired values.
key to go at the previous menu.
03/09/2015 Rev.1.2
Dose Time = 10 minutes.
T
= 10 minutes
Functioning = 50%
Cycle
CONSTANT FUNCTIONING
ENGLISH
33/100