HC997-999 – MOD. D
Digital multifunction solenoid metering pump
Settings menu – Date and clock
4.6.2
This menu allow to set the date and clock..
Press the
Press the
Press the
previous field.
Settings menu – Calibration
4.6.3
This menu allows to set the flow rate in mL of the pump in
100 strokes.
the delivery.
on the suction of the pump.
container (L1).
of chemical inside the container (L2).
that is the difference between L1- L2 and then press the
key to confirm.
Settings menu – Units of measurement
4.6.4
ADSP9000033
All manuals and user guides at all-guides.com
keys to set the desired values.
key to move the cursor on the next field, the value to modify is blinking.
key to go back at the previous menu or move the cursor at the
To perform the calibration following this procedure:
8.
Priming the pump, the chemical has to go out from
9.
Positioning a graduate container (at least 250 mL)
10. Save the quantity of the chemical inside the
11. Enter in the calibration menu and activate the pump.
12. A countdown will start.
13. When the pump stops, save the remaining quantity
14. Press the
This menu allows to set the units of measurement of the
pump's flow rate.
The units of measure L/h e mL/min are active only after the
calibration.
Press the
Press the
03/09/2015 Rev.1.2
SETTINGS AND CALIBRATION
keys to set the mL drawn
keys to scroll the menu entries..
key to select the desired entry.