Dear customer, thanks for choosing Wave Surfer, the new SICCE product,
EN
designed to simulate the natural movement of the sea in the marine aquariums.
IMPORTANT: Before use, please carefully read the following instructions to
enable the operational characteristics of this device at their best. Please save these instructions.
IMP�RTANT SAFETY INSTRUCTI�NS
• WARNING: ALWAYS disconnect all immersed electric devices before proceeding with
maintenance operations or putting your hands into the water; turn off the mains switch before
disconnecting the plug in case the plug, socket or power cable are wet.
• Check that the voltage and the frequency on the technical data label are the same as the
voltage and the frequency of your mains supply.
• Before supplying power to the product, verify that it is undamaged and that the power cable
and plug are intact.
• If the unit shows any kind of abnormal behaviour, immediately disconnect it from the mains
power supply.
• The power cable of this product cannot be replaced or repaired; in case of damage, replace
the entire unit.
• This product is designed for indoor use only, and has an IP20 protection rating; it should not
be turned on unless you have ensured that the unit is completely dry.
• Never put the device in the water and place it somewhere where it CANNOT fall into the water
or have contact with water.
• This unit is non-submersible. To avoid the possible risk of electric shock place the unit in a dry
place safe from splashing, moisture and salt creep, where it can't accidentally fall into water.
The unit can be anchored to a wall with 2 screws (not included).
• This unit is non-submersible. To avoid the possible risk of electric shock place the unit in a dry
place safe from splashing, moisture and salt creep, where it can't accidentally fall into water.
The unit can be anchored to a wall with 2 screws (not included).
• This product is designed for aquarium use only. Use in other applications may damage its
components, voiding the warranty immediately.
• We recommend using this product with SICCE Voyager pumps. In all other cases, do not attach
devices with power higher than 100W - 1.5 Amp to the power sockets on top of the unit.
• This unity cannot to be used by children unless they are under the supervision of a responsible
person, to ensure they can use the device safely.
• To disconnect a pump, do not pull the cable, hold both plug and unit firmly and remove plug
with care.
• To avoid water accidentally dripping onto the socket or the plug, curve the cable in a drip loop,
below the socket level ("DRIP LOOP").
• It is preferable to avoid the use of extensions for the cable. If an extension cable is necessary,
it should be of the correct rating, equivalent to the one provided with the product. We
recommend contacting a qualified technician for installation and connection.
• We recommend the unit be supplied through a RCD (Residual Current Device) with a nominal
residual current no higher than 30mA.
• The product does not need special maintenance, it is sufficient to remove regularly the dust or
the dirt sediments from the product and its surroundings.
INSTALLATION
WARNING: disconnect all the electric devices from the mains supply before putting your hands
into the water. Before switching the product on, check that it is undamaged and that the power
cable and plug are intact.
1 Remove the product form the box and completely unwind the power cable.
2
Place the unit in a dry place where it can't accidentally fall or anchor it to the wall with 2
screws (NOT INCLUDED) - N.B. The device cannot be put into water.
3
Place 1 or 2 pumps inside the tank.
4
Connect each pump to the Wave Surfer's socket/s respectively.
5 Check that the left knob (fig. 3) is set on "off".
6 Connect the unit to the mains power supply. Activate time-cycle with the left knob (fig. 3): a
green light (fig. 2/a) will show that the unit is operating and two blue lights (P1 and P2) will
show which pump is functioning.
7 Rotate the left knob (fig. 3) to set the required time-cycle.
8 Rotate the right knob (fig. 4) to set the distribution on each channel (refer to the examples in
Table 1).
EXTRA FUNCTI�NS:
FISH F��D - TIME SETTING (1 CLIC)
This special function is useful for the administration of food and medicines: with a single click
of the dedicate button (fig. 2/b) both channels, P1 and P2 (and their LEDs P1 and P2) will
deactivate for a pre-set duration of 4 MINUTES in order to stabilise the movement of water and
allow a correct absorption of the food, especially to the invertebrates.
Customise the duration of the "Fish Food" function - Proceed as follows:
1 Keep the FISH FOOD button pressed for 7 seconds until both P1 and P2 LED's flash
simultaneously.
2
Set the left knob on the preferred time.
3 Press the (b) button to confirm.
The last setting of the Fish Food mode is memorised and it will repeat every 24 hours.
To manually deactivate this function "CLIC" the same button again during Fish Food mode to
cancel it and it will repeat the next day only. In case you want to completely deactivate it, just press
the button for about 2 seconds during this mode, in case it is not active, it is sufficient to access
the control and deactivate as described previously. The green LED will flash to indicate that the
repetition was cancelled. At the next activation, the command will be repeated again.
In case of a power cut or if the product is disconnected from the mains during operation, the timer
resets. When the power supply is restored, Fish Food mode will start directly with the time set. In
case of personalisation of the Fish Food mode this remains memorised, but it will be necessary
to re-set the command to the preferred time.
NIGHT M�DE - TIME SETTING (2 sec. PRESS)
This function reduces water movement for 8 hours overnight. Hold down the dedicated button
(fig. 2/b) for about 2 SECONDS, the central LED (fig. 2/a) will start flashing to indicate the
mode was successfully set. This will deactivate the cycling of P2 for 8 HOURS (fixed time, not
customizable) then P2 will re-start the regular time-cycle.
The last setting of the Night mode is memorised and will be repeated every 24 hours.
To temporarily deactivate this function, "CLIC" the button during night mode. It will start again the
next day. To completely deactivate it, press the button for about 2 seconds during night mode, the
green LED will flash to communicate that the mode was cancelled successfully.
In case of a power cut or if the product is disconnected from the mains during operation, the
internal timer resets. When the supply is restored, the night mode will start automatically; it will
be necessary to exit this mode and re-program it to the preferred settings.
In case the product is turned OFF with the knob, the internal timer keeps working and keeps the
night mode memorised.
NOTE: this function only works if only two pumps are connected.