MAINTENANCE

Troubleshooting

Troubleshooting
Problem
No water flow from
pump
Low water flow from
the pump
Pump runs intermit-
tently

Replacement Parts

Item(s)
4, 5
For technical assistance, parts, or repair, please contact:
800.701.7894 | littlegiant.com
998290 Rev. 003 07/21
Probable Causes
There is no power to
pump
The pump is not priming
The pump trips its cir-
cuit breaker or GFCI
The pump intake is
blocked
The pump is not large
enough
The flow control valve is
mis-adjusted
The pump is too hot
Model(s)
PES-700-PW
PES-800-PW
PES-1000-PW
Corrective Action
Connect the pump to power.
Ensure that the inlet of the pump is below the water sur-
face.
Replace pump
Remove debris blocking the intake screen or impeller.
Select a larger capacity pump.
Turn the flow control valve until the desired flow is
reached.
Check to see that no debris is clogging the suction port.
Description
Impeller Kit
Order Number
166360
166361
166362
Franklin Electric Co., Inc. | Oklahoma City, OK 73157-2010