Technical Parameters; Temperature Sensor - Elko EP TEV-1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17

Technical parameters

Function:
Supply terminals:
Supply voltage:
Input:
Max. dissipated power
(Un + terminals):
Tolerance of supply voltage:
Measured circuit
Measuring terminals:
Temperature ranges
thermostat 1:
thermostat 2:
Hysteresis (sensitivity):
Sensor:
Faulty sensor indication:
Accuracy
Accuracy of settings (mech.):
Dependance on temperature:
Output
Number of contacts:
Rated current:
Switching output:
Peak current:
Switched voltage:
Output indication:
Mechanical life:
Electrical life:
Other information
Operation temperature:
Operation position:
Protection degree:
Overvoltage cathegory:
Pollution level:
2
Max. cable size (mm
):
Dimensions:
Weight:
Standards:

Temperature sensor

Range:
Scanning element:
In air / in water:
In air / in water:
Cable material:
Terminal material:
Protection degree:
Length:
Weight:
τ65 (95): time, which sensor needs to heat up on 65 (95) % of ambient temperature of
environment, in which is located.
Resistive values of sensors in dependance on temperature
Temperature (°C / °F)
20 / 68
30 / 86
40 / 104
50 / 122
60 / 140
70 / 158
Tolerance of sensor NTC 12 kΩ is ± 5% by 25 °C / 77 °F.
TEV-1
two-level thermostat
L - N
230 V AC / 50 - 60 Hz
max. 2.5 VA / 0.5 W
3 W
±15 %
T - T
-20 to +20 °C (-4 °F to +68 °F)
-20 to +20 °C (-4 °F to +68 °F)
3 °C (± 1.5 °C) / (37.4 °F (± 34.7 °F))
thermistor NTC 12 kΩ / 25 °C (77 °F )
red LED fl ashing
5 %
< 0.1 % / °C
1x changeover / SPDT (AgNi / Silver Alloy)
16 A / AC1
4000 VA / AC1; 384 W / DC
30 A / < 3 s
250 V AC1
LED
7
3x10
0.7x10
5
-30 to +50 °C (-22 to 122°F)
any
IP65 assembly
III.
2
solid wire 2.5 / with sleeve 1.5 (AWG 12)
110 x 135 x 66 mm (4.33˝x 5.3˝x 2.6˝)
270 g (9.5 oz.)
EN 60730-2-9, EN 61010-1
TZ-0
-40°C to +125°C (-40°F to 257°F)
NTC 12K 5 %
(τ65) 62 s / 8 s
(τ95) 216 s / 23 s
Silicone
Nickel plated copper
IP67
110 mm (4.3")
4.5 g (0.16 oz.)
Sensor NTC (kΩ)
14.7
9.8
6.6
4.6
3.2
2.3
Function
Un
T1
T2
V1
red LED
green LED
orange LED
h) hysteresis
TEV-1 is a double thermostat designated for system of protection of roof watershoots
against freezing. The device is placed in a waterproof box (IP65), sensor with double
insulation, which is a part of the device, senses ambientrature. The device operates
as zonal thermostata with independent setting of upper and bottom operational
temperature. In case the ambient temperature is higher than T1 (upper temperature),
thermostat switches heating of watershoots off (icing melts down). In case the ambient
temperature is lower than T2 (bottom temperature),thermostat also switches heating off
(to big freezing heating cannot manage to melt the ice).
Warning
The device is constructed to be connected into 1-phase main and must be installed in
accordance with regulations and norms applicable in a particular country. Installation,
connection and setting can be done only by a person with an adequate electro-technical
qualifi cation which has read and understood this instruction manual and product
functions. The device contains protections against over-voltage peaks and disturbing
elements in the supply main. Too ensure correct function of these protection elements
it is necessary to front-end other protective elements of higher degree (A, B, C) and
screening of disturbances of switched devices (contactors, motors, inductive load etc.) as
it is stated in a standard. Before you start with installation, make sure that the device is
not energized and that the main switch is OFF. Do not install the device to the sources of
excessive electromagnetic disturbances. By correct installation, ensure good air circulation
so the maximal allowed operational temperature is not exceeded in case of permanent
operation and higher ambient temperature. While installing the device use screwdriver
width approx. 2 mm. Keep in mind that this device is fully electronic while installing.
Correct function of the device is also depended on transportation, storing and handling.
In case you notice any signs of damage, deformation, malfunction or missing piece, do
not install this device and claim it at the seller. After operational life treat the product as
electronic waste.
2 / 2
h
h
sensor
failure

Publicidad

Tabla de contenido
loading

Tabla de contenido