Samoa 561610 Guía De Servicio Técnico Y Recambio página 2

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 4
EN
INSTALLATION
Electric pump with sinter steel gears and molted iron body, with direct
coupling to en electric motor, which can be either single phase (models
561617, 561616, 561615, 561614 and 561611) or three phase of high
efficiency IE2 (561613 and 561610).
Electrical connection
These pumps are distributed without cable (Except for 561616 and
561617 models).
To connect the electric motor to a line, remove the top cover connect the
pump to the line according to fig. 2. Do always employ intallation cables etc.
according to the electrical information given under "Technical Data"
-Electrical information.
TANK CONNECTION
Pos
Description
A
Shut-off valve
B
Outtlet valve
C
Connection adaptor
D
Gear pump
E
Connetion adaptor
F
Filter
G
Suction hose
H
Shut-off valve
I
Adaptor
J
Adaptor
!
ATTENTION: Before starting the pump, wet the inside of the pump
body with oil through the inlet and outlet openings. The starting
phase may take from several seconds to a few minutes, depending on
the characteristics of the system.
The distance in height between the oil level and the pump inlet must
not be more than 5 m.
To start the gear pump, make sure that the outlet valve is open.
2
856 804 R. 12/21
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
Recommended for pumping high viscosity oil, up to ISO VG 450 cts.
Mechanical installation
These electric pumps must be installed on a horizontal base.
The suction hose diameter should be the same or bigger than the pump
inlet diameter.
See fig. 3 for typical installations with all the recommended accesories
for the pump to operate correctly.
THREE PHASE
Fig. 2
Fig. 3
CAPACITOR
SINGLE PHASE

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

561614561617561611561615561613561616

Tabla de contenido