6
RS-485/NETWORK SET
[Settings] (
indicates default setting.)
Item
Setting
REMOTE AS
VCR
(1)
DVR
DATA SPEED
(2)
STATUS INFO
ON
(3)
OFF
ALARM INFO
ON
(4)
OFF
ADDRESS*
(5)
3
Press the [
] and [
the desired item, then press the [
button.
4
Press the [
] and [
change the setting, then press the
[
] button.
5
Use the same procedure to set the other
items as needed.
6
Press the [EXIT/OSD] button.
The display returns to the normal screen.
Setting REMOTE SET
Use the following procedure to specify whether or not
recording is to be stopped when the [REC] button on the
separately-sold VA-RMN01 wired remote controller is
pressed. When a setting of "ENABLE" has been made, the
remote controller's [REC] button can be pressed for 2
seconds or longer to stop recording.
Regardless of this setting, if the [REC] button is pressed
and released quickly (i.e., within 2 seconds), recording
will be started.
English
All manuals and user guides at all-guides.com
Description
When the digital video recorder is operated
from a controller, sets it to operate as a
VCR. Use VCR when using VSP-7000.
When the digital video recorder is operated
from a controller, sets it to operate as a
digital video recorder.
Used to select the communication speed.
Selections: 19200/2400/4800/9600
Status information is sent.
Status information is not sent.
Alarm information is sent.
Alarm information is not sent.
Set the digital video recorder's address
when using RS-485.
Setting range: 000 to 127
] buttons to select
]
] buttons to
1
Press the [MENU] button.
The MENU indicator lights up and the <MAIN MENU>
screen appears.
Select "6.RS-485/NETWORK/REMOTE SET" and press
the [
] button.
The <RS-485/NETWORK/REMOTE SET> screen
appears.
2
Press the [
] and [
"REC STOP" and press the [
button.
"DISABLE" flashes.
3
Press the [
] and [
change the setting, then press the
[
] button.
[Settings] (
indicates initial setting.)
Setting
DISABLE
Recording will not be stopped when the remote
controller's [REC] button is pressed.
ENABLE
Recording will be stopped when the remote
controller's [REC] button is pressed for at least
2 seconds.
4
Press the [EXIT/OSD] button.
The display returns to the normal screen.
41
] buttons to select
]
] buttons to
Description