BDACM1000
DESCRIPTION
Device overview
① Clamp. Used to enclose the wire.
(Observe the direction of current flow).
1
② Rotary switch. Used to select measurement
functions.
③ Keypad. Measurement function keys.
④ LCD display. Shows measurement results
and various symbols.
⑤
2
7
Terminal for the red test lead for voltage,
3
resistance, capacitance, frequency,
4
temperature, diode test and continuity
measurements.
⑥ COM. Terminal for the black test lead as a
6
5
common reference point.
⑦ Clamp opening actuator.
LCD Display
The LCD screen is shown in Figure 2-2 and the meaning of each symbol is
described in Table 1:
No.
Symbol
1
Indicates negative readings.
The device is in autorange mode, in which the device
2
AUTO
automatically selects the range with the best resolution.
AC
3
Indicates AC voltage or current.
DC
4
Indicates DC voltage or current.
5
Low battery indication.
6
H
The device is in Data Hold mode.
7
REL
The device is in Relative Measurement mode.
8
MAX
Display maximum data.
9
MIN
Display minimum data.
10
The device is in Continuity Check mode.
11
The device is in Diode Test mode.
Ω
%ºCºF KM
Hz
12
Measurement units.
nμmFAV
This symbol means that the input is too high for the
13
selected range.
Auto power off function indication.
Meaning