22 | English
▪ <Audio Signals>: <ON>/<OFF>
Under this menu item, you can switch the audio signals
on or off.
▪ <Shutdown Time>
Under this menu item, you can select the time interval
after which the measuring tool will automatically
switch off if no buttons are pressed. You can also deac-
tivate automatic switch-off by selecting the <Never>
setting.
▪ <Delete All Images>
Under this menu item, you can delete all the files in the
internal memory at once. Press the right-hand arrow
button (8) for <More> to enter this submenu. Then
press either the left-hand function button (13) to de-
lete all files, or the right-hand function button (7) to
cancel.
▪ <Tool Information>
Under this menu item, you can access information
about the measuring tool. There you will find the serial
number of the measuring tool and the installed soft-
ware version.
You can also press the measuring button (17) to exit any
menu and return to the home screen.
Documenting Measurements
Saving Measurements
The measuring tool begins to take measurements as soon as
it is switched on and does so continuously until it is switched
off.
To save an image, point the camera at the required measur-
ing object and press the "Save" button (11). The image is
saved in the internal memory of the measuring tool. Alternat-
ively, press the measuring button (17) (pause). The meas-
urement is frozen and shown in the display. This enables you
to carefully view the image and to make retrospective adjust-
ments (e.g. to the colour palette). If you do not wish to save
the frozen image, restart measuring mode by pressing the
measuring button (17). If you wish to save the image in the
internal memory of the measuring tool, press the "Save"
button (11).
Calling Up Saved Images
Proceed as follows to call up saved thermal images:
– Press the left-hand function button (13). The most re-
cently saved photo now appears in the display.
– Press the right-hand (8) or left-hand (12) arrow button to
switch between the saved thermal images.
You can also display the thermal image taken as a full-screen
image by pressing on the up arrow button (5).
Deleting saved images
Change to the gallery view to delete individual thermal im-
ages:
– Press the right-hand function button (7) under the waste
paper basket symbol.
– Confirm the process by pressing the left-hand function
button (13) or cancel the deletion by pressing the right-
hand function button (7).
1 609 92A 6KU | (06.10.2021)
<Delete All Images>
In the <Delete All Images> menu, you can delete all the files
in the internal memory at the same time. Press the Func (6)
button to call up the measuring functions. Now press the
right-hand function button (7) and select <Tool> → <Delete
All Images>. Press the right-hand arrow button (8) to enter
this submenu. Then press either the left-hand function
button (13) to delete all files, or the right-hand function
button (7) to cancel.

Data Transfer

Data Transfer via USB Port
Open the cover on the micro USB port (3). Connect the mi-
cro USB port (4) of the measuring tool to your computer via
the micro USB cable (24) provided.
Now press the on/off button (9) to switch on the measuring
tool.
Open the file browser on your computer and select the
GTC_400C drive. The saved files can be copied from the in-
ternal memory of the measuring tool, moved to your com-
puter or deleted.
As soon as you have finished the required operation, discon-
nect the drive from the computer following the standard pro-
cedure and then use the on/off button (9) to switch the
measuring tool off again.
Caution: Always disconnect the drive from your operating
system first (eject drive), as failure to do so may damage the
internal memory of the measuring tool.
Remove the micro USB cable during the measurement oper-
ation and close the cover (3).
Always keep the flap of the USB port closed so that dust and
splashes cannot enter the housing.
Note: Use USB to connect the measuring tool to a computer
only. The measuring tool may be damaged if connected to
other devices.
Post-Editing the Thermal Images
You can post-edit the saved thermal images on your com-
puter if it uses a Windows operating system. To do so, down-
load the GTC Transfer software from the product page for
the measuring tool at
www.bosch-professional.com/thermal.
Data transmission via WLAN
The measuring tool is equipped with a Wi-Fi interface which
enables the saved images taken by your measuring tool to be
wirelessly transmitted to a mobile device.
Special Bosch applications (apps) are available for this use.
They can be downloaded in the store corresponding to your
device:
In addition to the wireless data transfer of your images, the
Bosch applications make it possible for you to use an exten-
ded range of functions and make it easier to post-edit and
forward measured data (e.g. via e-mail). Information about
Bosch Power Tools

Publicidad