Dc Current Measurement; Resistance Measurement - Velleman DVM832 Manual Del Usuario

Ocultar thumbs Ver también para DVM832:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48
3.
Connect the test leads to the source being measured.
4.
Read the voltage value on the LCD display along with
the polarity of the red lead connection.
10.2 AC VOLTAGE MEASUREMENT
1.
Connect the red test lead to the "VmA" jack and the
black test lead to the "COM" jack.
2.
Set the rotary switch in the appropriate V~ position.
3.
Connect the test leads to the source to be measured.
4.
Read the voltage value on the LCD display.

11. DC Current Measurement

Do not measure circuits that may contain voltages
> 500 V
Use extreme caution when measuring voltages
higher than 60 VDC.
Always place your fingers behind the protective
edges of the test probes while measuring!
1.
Connect the red test lead to the "VmA" jack and the
black test lead to the "COM" jack (switch the red lead
to the "10A" jack for measurements between 200 mA
and 10 A).
2.
Set the rotary switch (DCA) in the desired position.
3.
Open the circuit in which the current is to be
measured and connect the test leads to the circuit IN
SERIES.
4.
Read the current value and the polarity of the red
lead connection on the LCD display

12. Resistance Measurement

Do not conduct resistance measurements on live
circuits. Make sure all capacitors in the circuit are
depleted.
V. 05 – 05/01/2022
DVM832
13
©Velleman Group nv

Publicidad

Tabla de contenido
loading

Tabla de contenido