Reversing switch action
A
► 1. Reversing switch lever
LED indicator / Beeper
► 1. LED indicator
LED indicator / Beeper on the tool shows the following functions.
Function
Check of the LED indi-
cator, light and beeper
operation
Detection of switch
trigger operation when
installing battery
Auto-stop with fastening
completion
Alarm against insuffi-
cient fastening
Intermission between
the phases
Double-hitting detection
1
Status of the tool
When the battery car-
Lights up first in green,
tridge is installed, the tool
next red.
checks for its LED indica-
(And then the light
tor, light and beeper.
comes on.)
When the battery cartridge
Blinks in red and green
is installed with the switch
alternatively.
trigger pulled, the tool stops
to avoid unintentional start.
The tool setting has
Lights up in green for
been achieved and the
approximately one
tool has stopped.
second.
The tool has not com-
Lights up in red.
pleted the tool setting
because the switch trigger
has released before
reaching the set values.
Otherwise, the settings of
"Failure Criteria for Phase"
has been achieved.
The tool is in the inter-
Lights up or blinks in
mitting period configured
green (depending on
by the setting of "Shift to
settings)
the next Phase".
When the operator
Lights up in red.
starts to re-fasten an
already-fastened screw,
the tool detect it and stops.
CAUTION:
rotation before operation.
CAUTION:
the tool comes to a complete stop. Changing the
direction of rotation before the tool stops may dam-
age the tool.
CAUTION:
always set the reversing switch lever to the neu-
tral position.
This tool has a reversing switch to change the direction
B
of rotation. Depress the reversing switch lever from the
A side for clockwise rotation or from the B side for coun-
terclockwise rotation.
When the reversing switch lever is in the neutral posi-
tion, the switch trigger cannot be pulled.
1
Status of the LED indicator/beeper
LED indicator
A series of very short
beeps
A series of short beeps
A long beep
A long beep
7 ENGLISH
Always check the direction of
Use the reversing switch only after
When not operating the tool,
Action to be taken
Beeper
Release the switch
trigger.
–
Retighten the screw.
–
–
–
–
–