Quick Start Guide
Pedestal Sump Pump
1. Attach discharge pipe to the pump discharge. Drill a
1/8" anti-airlock hole as shown.
2. Connect a check valve to the discharge pipe.
Be sure the flow is away from the pump.
Check Valve
Discharge Pipe
Discharge size:
Model SPP05001K: 1-1/2 in. FNPT
or 1-1/4 in. FNPT (with adaptor)
Model SPP03301K: 1-1/4 in. FNPT
1/8" Anti-airlock hole
NOTE: The Float Switch comes pre-assembled. Refer to your owner's manual if you need to adjust the ON and OFF position of the float switch.
3. Ensure Pit/Basin is clear of all debris. Lower the pump into
the center of the sump pit or sump basin. Pit/Basin should
be at least 12" diameter and 18" deep.
Minimum
12" Dia.
Read your manual for installation, operation, and safety information.
This guide neither supplements nor replaces the Owner's Manual.
4. Plug into a GFCI protected outlet.
5. Check the pump's operation by filling the sump pit or
basin with water.
GFCI Outlet
Minimum
18" Deep
Copyright © 2021, GP Enterprises Co., Ltd.
K2-SPL-1 (Rev. 7/28/21)

Publicidad

loading

Resumen de contenidos para K2 Pumps SPP03301K

  • Página 1 Check Valve GFCI Outlet Discharge Pipe Discharge size: Model SPP05001K: 1-1/2 in. FNPT or 1-1/4 in. FNPT (with adaptor) Model SPP03301K: 1-1/4 in. FNPT Minimum 18” Deep 1/8” Anti-airlock hole Minimum 12” Dia. NOTE: The Float Switch comes pre-assembled. Refer to your owner’s manual if you need to adjust the ON and OFF position of the float switch.