Electrical data
Maximum power consump-
tion
DC supply voltage from
PELV for switching outputs
For a definition of PELV, please refer to the "General electrical information" chapter in the HEIDENHAIN brochure
entitled "Interfaces of HEIDENHAIN Encoders."
Interfaces
EIB 5181
HEIDENHAIN | EIB 5000 | Operating Instructions | 11/2020
EIB 5181
Maximum
350 mW
current
consump-
tion:
EIB 5212 and EIB 5282
0 V to 36 V
For connection to the PLC logic input (max. switching capacity: 32 mW)
Input:
X136:
Temperature sensor
X401:
1 V
, EnDat 2.1, EnDat 2.2 (25-pin D-sub, male)
PP
Output:
X421:
1 V
, EnDat 2.1, EnDat 2.2 (25-pin D-sub, female), EnDat 2.2: cable length:
PP
max. 3 m
X108:
Shield connection of temperature sensor
X75:
Reserved, do not use
EIB 5211
EIB 5212
EIB 5281
210 mW
260 mW
260 mW
EIB 5282
300 mW
61