Cleaning
Before cleaning, disconnect the voltage tester from all
measuring circuits. If the instruments have become dirty
due to daily use, they can be cleaned with a damp cloth
and a little mild household detergent. Never use aggressive
detergents or solvents for cleaning. After cleaning, do not
use the instrument until it is completely dry.

BATTERY REPLACEMENT

2100-Alpha: In case of discharged batteries, the LED Low
18
battery indication
is ON. Replace the batteries.
2100-Beta and 2100-Gamma: In case of discharged
batteries, the LCD will show "
• Disconnect the voltage tester completely from all
measuring circuits.
• Using a screwdriver, unscrew the two metal screws
on the battery compartment until the battery
compartment cover can be removed.
NOTE: Do not unscrew the screws completely.
• Remove used batteries.
• Insert new batteries, type 1.5 V IEC LR03. Ensure that
the polarity is correct.
• Correctly insert battery compartment cover and screw
down.
W
If batteries have leaked, the instrument must no
longer be used and must be tested by our Factory Service
Department before it can be used again.
W
Never attempt to dismantle a battery cell! The
electrolyte in the cell is extremely alkaline and electro
conductive. Risk of chemical burns! If electrolyte comes
into contact with your skin or clothing, these spots must
be rinsed immediately with water. If electrolyte gets into
your eyes, rinse them immediately with clean water and
consult a doctor. Please bear this in mind and also consider
our environment. Do not throw used batteries into the
normal household waste, but hand the batteries over to
hazardous waste facilities or hazardous waste collection
centers.
W
Observe the currently valid national or local regulations
concerning the return, recycling and disposal of used
batteries and accumulators.
W
Do not use the voltage tester with open battery
compartment!
15
". Replace the batteries.
Screws