EdilKamin SERBATOIO Instalación Uso Y Mantenimiento página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
FASTENING THE PROBES
Probe for detecting the "Minimum pellet" level IN THE TANK ON THE BOILER.
- Secure the probe to the perforated galvanized plate (1 - supplied) using the ferrules on the probe itself (photos 17-17a).
- Remove the blind plate (2 – photos 18-18a) on the rear of the boiler and replace it by screwing the plate (1),
complete with the probe, into position 3 (photo 18b).
Probe for detecting the "Minimum pellet" level IN THE EXTERNAL TANK.
- Remove the closing plate (4 - photo 19) and open the pre-cut hole (5) on the plate itself.
- Secure the probe to the plate (4) using the ferrules on the probe itself (photos 19a-19b).
- The probe should protrude approximately 5/10 mm from the inner ferrule (photo 19c).
- Reposition the plate (4 – photo 20) (with the inscription "UP 250" facing upwards), being careful not to damage
the electrical cable.
Verify the probes' proper installation by checking that the led indicators corresponding to the appropriate icons
light up on the electronic regulator's display (see fig. 22 on page 15).
MAKE SURE THAT THE PROBE DOES NOT COME INTO CONTACT WITH HEAT SOURCES (e.g.
SMOKE OUTLET).
4
5
Pic 19
INSTALLATION
1
Pic 17
1
Pic 17a
Pic 18
Pic 19a
Pic 19b
2
4
4
14
2
Pic 18a
3
Pic 19c
4
external
4
Pic 20
Pic 18b
5/10 mm
internal

Publicidad

Tabla de contenido
loading

Tabla de contenido