Tripp-Lite NFI-U05 Manual Del Usuario página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Wiring Requirements
NFI-U08-2 with 2-Pin Terminal Block
You can use "PWR" for Power input. Top view of the Terminal Block is
shown in the figure below:
Terminal Block
Terminal
Block
CAUTION:
• Use copper conductors only.
• Wiring cable temperature should support at least 105°C.
• Tighten the wire to a torque value 4.5 lb.in.
Note: The NFI-U08-2 wire gauge for the terminal block should range between 12
and 24 AWG. Power input is 18~30VDC at a maximum of 0.2A DC power.
To insert power wire and connect the 12~48VDC at a maximum of 0.2A
DC power to the power terminal block, follow these steps:
• Use a flat-head screwdriver to loosen the wire-clamp screws.
• Insert the negative/positive DC wires into the PWR-/PWR+ terminals,
respectively.
• Tighten the wire-clamp screws to prevent the wires from loosening.
ATTENTION: Use a power supply from 12~48VDC. The device power
shall be supplied by 61010-2-301 R/C power with SELV, Limited energy
output.
DIN Rail
Grounding
Screw
Power Input
Top View
Grounding
Screw
12
PWR
100 Mbps
LNK/ACT
Front View