Mounting
Checking that the board has been mounted correctly
Turn on the power of the AV-HS450 (to both the control panel and mainframe), and use
the menu for displaying the statuses of the option boards to check that the board has
been mounted correctly.
Press the [SYSTEM] button to light its indicator, and display the SYSTEM menu.
Turn [F1] to display the OptVer sub menu.
<Menu display>
14 | Select | Board
| Version |
SYS
OptVer
|
SLOTB| 3D-OUT|
Turn [F2] to select the "SLOTB" using the Select item.
If the board has been mounted correctly, "3D-OUT" will appear at the Board item.
If the board has not been mounted correctly or if the AV-HS450 software is a
version below "2.00.00", "None" will appear for the Board item (or the Board item
display may go blank).
Removal procedure
Remove this board by following the procedures for mounting it in reverse.
When attaching the blank panel, position the panel so that the part with the protrusion
is facing down, and then attach it.
|
19 (E)
Connections
Connections when not implementing gen-lock (frame synchronizer ON)
HD SDI (R ch)
HD SDI
(L ch)
Rig 3D cameras
SLOT A
SLOT B
IN/OUT A1
IN/OUT A2
SDI INPUTS
1
2
3
4
5
6
7
8
9
SDI OUTPUTS
DVI-D OUTPUTS
1
2
3
4
5
6
HD SDI
(L ch)
HD SDI
(R ch)
3D-compatible
SDI monitor
HD SDI
SDI monitor
DVI-D
PC monitor
Make the connection with this board while the power is off.
For details on connecting individual devices, refer to the respective Operating
Instructions.
For details on operating individual devices, refer to the respective Operating
Instructions.
HD SDI (L ch)
HD SDI (R ch)
Integrated twin-lens
3D camera
HD SDI (L ch)
HD SDI (R ch)
3D-compatible
SDI monitor
IN/OUT B1
IN/OUT B2
3D SDI OUTPUTS
OUT
OUT
10
11
12
13
14
15
16
C/C
U/C
EDITOR
REF
SIGNAL
GND
LAN
PANEL
TALLY/GPI
COM
Multi-format Live
Switcher
AV-HS450
Power cord
LCD CONTRAST
SERVICE
NORMAL
TALLY / GPI
MAINFRAME
12V IN 1
AC adapter
20 (E)
12V IN 2
POWER
ON
SIGNAL
GND