Cod. 970073EIPb V04_21
IN1
IN1 input WG D0
IN2
IN2 input WG D1
GND
Signal ground
IN3
IN3 input WG D0
IN4
IN4 input WG D1
GND
Signal ground
Table 2: Power Supply LEDs
LED
Function
AC
Vac supply available
DC
12Vdc output available
Table 3: Status LEDs
Function in normal mode
LED1
Normal mode
LED2
None
LED3
Blinking: Low level configuration error
ON: High level configuration error
LED4
No memory card/ Memory card error
LED5
Event log error
LED6
License error
LED7
Not used
LED8
Blinking: Proper functioning in normal mode
Table 4: Technical Specification
Supply voltage
Backup battery
Current consumption
Inputs
Relay outputs
Transistor outputs
Power supply outputs
RS485 ports
Ethernet port
Wire lengths
Environmental class
(acc. to EN 50131-1)
Dimensions H x W x D
B1
CLK
DTA
GND
A2
B2
11.5Vdc-15Vdc, nominal 12Vdc,
13.8Vdc/7Ah, charging current 300mA
100 mA for 18Vac (no loads on AUX/TML)
Eight inputs, electrically biased to +12Vdc via 5.6kΩ resistor
Two relay outputs with single NO/NC contact 30Vac-dc/1.5A rated
Six open collector transistor outputs, 15Vdc/150mA rated. Max. total
current sink by all outputs up to 3A dc.
12Vdc/0.2A (TML)
Two RS485 communication ports
10BASE-T 10/100Mb communication port
1200m for RS485
150m for Wiegand and AC-MAX CLK/DTA
Class I, indoor general conditions, temperature: +5°C to +40°C, relative
humidity: 10 to 95% (no condensation)
72 x 175 x 30 mm
RS485(1)/ Line B from EXP2D/EXP4D if
exist fingerprints readers.
Transistor output
Transistor output
Signal ground
x NO FUNCTION
x NO FUNCTION
Function in service mode
None
Service mode
not used
Unknown error
IP address error
Memory card error
Not used