Always empty, clean, and drain the tank after every use
as directed in the Maintenance section.
Turn off the sprayer and remove the battery pack.
Unscrew the tank from the sprayer.
Return any unused fluid to its original container, and
thoroughly clean the sprayer.
Review chemical SDS sheet how best to secure and store
your chemical solution when not in use.
Thoroughly clean the sprayer before storing or before
switching to a different chemical. See Cleaning the Unit
later in this manual.
NOTE: Wipe the outside of the tank with a dry cloth and
clean up any spills before inserting the tank.
WARNING:
Always flush unit when you change chemical products.
Do not mix or combine chemicals.
When you are finished with the sprayer, thoroughly wash
your hands and any area where skin has been exposed
to the mist.
CONNECTING AN ACCESSORY TANK
See Figure 7.
WARNING:
Fluid may escape from the quick connect if the tank is
not fully drained. Be cautious, and wear the appropriate
protective equipment as specified on the chemicals
packaging, SDS sheet, or EPA master label.
The sprayer is equipped with a quick connect outlet which
allows the user to connect a quick connect hose and acces-
sory tank to the sprayer for larger applications. (Accessory
tank and quick connect hose not included.)
WARNING:
To avoid serious personal injury, always remove the
battery pack from the tool when cleaning or performing
any maintenance.
OPERATION
To attach accessory tank:
Pull back the quick connect collar on the tank.
Remove the sprayer by pulling it from the quick connect
Pull back the quick-connect collar on the hose.
Push the male barb on the sprayer into the female quick
Push the collar forward so that the hose is secured properly.
Pull on the hose to be certain it is properly secured.
To disconnect accessory tank:
Pull back the quick-connect collar on the hose.
Remove the sprayer by pulling it from the quick-connect
OPERATING TIPS
Never point the spray end of the sprayer at yourself or
Avoid spraying/fogging on windy days. Mist can be
Never point sprayer in the direction of people or animals;
Especially in warmer weather, use sprayer in the early
Never smoke, eat, or drink while operating the sprayer.
For household use only.
MAINTENANCE
Always wear eye protection with side shields or goggles
marked to comply with ANSI Z87.1. Failure to do so could
result in fluids entering your eyes resulting in possible
serious injury.
9 — English
collar.
connect on the hose.
collar.
others.
accidentally blown onto plants or objects that should not
be sprayed.
always direct downwind.
morning or late afternoon. Excessive heat can evaporate
the mist before it settles.
WARNING: