ASSEMBLY DIAGRAM XILO D 24 MCS W TOP - card code 4.56035.0
L
J1
F
N
L1
J14
T A
BM
SR
SS
RLA
LEGEND
Modulating coil
BM
CiR
Heating circulator
EA
Ignition electrode
Control electrode
EC
Fuse 2(A)
F
JP1
Methane/LPG selector
JP3
Post-circulation selector
Ignition limiting selector
JP4
JP5
Jumper to be cut for low temperature
JP6
Mono-thermal/bi-thermal switch
Phase 230 V 50 Hz
L
N
Neutral
Warning: One of the two gas valves only, VG or VG1, is fitted on the boiler.
All manuals and user guides at all-guides.com
VN
C iR
J3
J4
J12
J8
J9
J6
JUMPER TO BE CUT IF LIMIT
JP3
JP1
THERMOSTAT
JP5
IS REQUIRED
JP4
JP2
R max.
3
Lock-out warning light
ON/OFF warning light
MP
H ot water priority micro
pressure switch
PA
Air pressure switch
PS
No-water pressure switch
Slow ignition power adjustment
RLA
Rmax. Heating max. power adjustment
SR
Heating sensor
SS
Hot water sensor
Room thermostat (if any)
TA
TL
Limit thermostat (if any)
TST
Safety thermostat
Gas valve SIT 837
VG
TST
V G
V G 1
PS
PA
TL
(LOW
TEMPERATURE)
MP
+
S
J10
J13
PANEL
CONNECTION
2
1
Malfunction warning light
EA
EC
J15
VG1
Gas valve Honeywell
VK 4105M
VN
Fan
1
Heating potentiometer
Selector: Off
2
Summer
Winter
Reset
Test
3
Hot water potentiometer
38