ASSEMBLY DIAGRAM XILO D 24 MC W TOP - card code 4.55828.0
L
J1
F
N
L1
J14
TA
BM
SR
SS
LEGEND
BM
Modulating coil
CiR
Heating circulator
EA
Ignition electrode
Control electrode
EC
F
Fuse 2(A)
FC
Flue control
Methane/LPG selector
JP1
JP3
Post-circulation selector
JP4
Ignition limiting selector
Jumper to be cut for low temperature
JP5
Warning: One of the two gas valves only, VG or VG1, is fitted on the boiler.
All manuals and user guides at all-guides.com
CiR
J3
J8
J9
J6
JUMPER TO BE CUT IF LIMIT
JP3
THERMOSTAT
JP1
IS REQUIRED
JP5
(LOW TEMPERATURE)
JP4
RLA
Rmax .
3
Lock-out warning light
ON/OFF warning light
Phase 230 V 50 Hz
L
N
Neutral
MP
Hot water priority micro pressure
switch
No-water pressure switch
PS
RLA
Slow ignition power adjustment
Rmax. Heating max. power adjustment
Heating sensor
SR
SS
Hot water sensor
Room thermostat (if any)
TA
TST
VG
J12
PS
FC
TL
MP
+
S
J10
J13
PANEL
CONNECTION
2
1
Malfunction warning light
EA
EC
J15
TL
Limit thermostat (if any)
TST
Safety thermostat
VG
Gas valve
1
Heating potentiometer
Selector: Off
2
Summer
Winter
Reset
Test
3
Hot water potentiometer
39